Adjustment Of The Xy Table Detector - JUKI PLK-J12060RH Technical Manual

Industrial sewing machine
Table of Contents

Advertisement

7-6. Adjustment of the XY table detector

XY table detecting position is front left corner of sawing area to the needle center. At the first origin
movement when turn the machine power on, XY table moves toward above position. After detection, XY
table is back to the home position as shown in the following figure.
NOTE When modify the home position somewhere other than the center of sewing area, please refer to
the instructions OPERATION PANEL technical manual [18] [Easy setting 3-(5)].
<4>
<3>
500 (600) 500(600)
1000 (1200)
Home position
<1>: X detect plate <2>: X detector <3>: Y detect plate <4>: Y detector <5>: Needle
<1>
<2>
<5>
(
) dimensions: for PLK-J12060RH
- 40 -
<5>
1000 (1200)
Detecting position

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plk-j10050rh

Table of Contents