Outdoor unit installation - mounting dimensions
Prepare the installation base of the unit according to the dimensions below.
Model
7 kW
9-11 kW
13-18 kW
W
Multiple units
L ≤ H
L > H
16 |
Outdoor unit W x D x H
890 x 342 x 673 mm
946 x 410 x 810 mm
952 x 415 x 1333 mm
H
L
A
L ≤ ½ H
25 cm or more
½ H < L ≤ H
30 cm or more
Cannot be installed
Mounting dimensions
Distance A
663 mm
673 mm
634 mm
W
H
D
Distance B
354 mm
403 mm
404 mm
A
B