Graco Husky 307 Instructions-Parts List Manual page 19

Air-operated diaphragm pumps
Table of Contents

Advertisement

Reassembly
1. If the detent collar (7) was removed, carefully
install a new collar in a new cover (2), using a
rubber mallet. See Fig. 12.
2. Grease the spring (6) and place it in the collar (7).
Grease the ball (8) and set it on the spring.
3. Grease the o-ring (20) and install it in the hole (H)
in the cover (2). See Fig. 12. Slide the washer (18)
onto the blunt end of the reset shaft (21). Insert
the shaft through the cover (2) until it seats.
4. Grease the spring (3). Place the link stop (4) inside
the spring.
1
Apply grease (26{).
2
Press fit with rubber
mallet.
{21
1
{18
{20
1
H
Fig. 12
5. Grease the detent link (22) and link spacer (17).
Assemble the detent link, link spacer, and actuator
link (16) as shown in Fig. 13. The raised bumps on
the links (22 and 16) must face up.
Service
{8
1
6{
1
7{
2
2{
01437
6. Squeeze the spring (3) and install it and the stop
(4) in the link assembly. The spring tension will
hold all these parts together. Grease the valve cup
(5) and install it in the link assembly as shown.
7. Install the link assembly on the cover (2) so the
pointed end of the reset shaft (21) fits through the
holes in the links and the square part of the shaft
engages the square hole. Make certain the bumps
on the detent link (22) engage the ball (8).
1
Apply grease (26{).
2
Bumps face up.
Reset shaft square must engage
3
with square hole.
2
{16
1
{17
1
{22
1
3
1
Fig. 13
2
5{
1
4{
1
8{
{3
2{
7505A
308553
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents