PRINTER ENGINE SERVICE MODE
SP2
Mode Number
2109*
06
LD Unit Position
07
Pitch Change Count
08
Beam Pitch Data Reset
2110
01
Test Mode dpi
2112
01
Polygon Motor Off Timer
2201*
Development Bias
01
Image Development Bias
02
ID Sensor Pattern
2207
01
Forced Toner Supply
Function and [Setting]
Displays the current LD unit position (number of
pulses from home position). If this is different
from the value of SP2109-01 or SP2109-02, LD
unit positioning has failed.
Displays how many times the LD unit position
has been changed (how many times the
resolution has changed.)
When the laser beam pitch adjustment is done,
this counter is reset to zero.
Resets the values of SP2109-06 and SP2109-
07.
After replacing the LD unit, this SP mode must
be performed. See section 3.9.5.
Sets the scanning resolution (dpi).
[See below / 8 / 0 ~ 18]
Range
0: 400 x 400 dpi
1: 391 x 406 dpi
2: 406 x 391 dpi
4: 300 x 300 dpi
8: 600 x 600 dpi
15: 439 x 430 dpi
16: 476 x 476 dpi
17: 483 x 465 dpi
18: 465 x 483 dpi
Input the time that the polygon motor is to switch
off after the printer has remained idle for the
specified time and entered the standby mode.
If set to zero, the polygon motor never switches
off in standby mode. However, if the machine
enters the energy saver mode, the polygon
motor will ignore the zero setting and switch
itself off.
[0~60 s / 10 s / 5 s step]
Adjusts the development bias for printing.
Use as a temporary measure to correct faint
images printed with an aging drum.
[–200 ~ –700 / 540 V / 10 V step]
Adjusts the development bias for the ID sensor
pattern for V
(ID sensor output after reading
SP
the ID sensor pattern).
[–200 ~ –700 / 380 V / 10 V step]
Forces the toner bottle to supply toner at 1-
second intervals for up to 30 seconds. To start,
press #(Enter).