VIII. BASE UNIT-3 (READING RELATION)

1. Lower Reading Unit

Note: A short screwdriver is required to re-
move this part. If it is not available,
remove the entire upper unit.
1) Remove the registration lower roller.
(Page 3-33)
2) Remove the reading lower roller.
(Page 3-38)
3) Remove the screw
round tip), and the grounding cable
relay connector
3
holder
, remove the relay connector
4
then remove the reading unit's cable
from the cable holder.
Figure 3-801
COPYRIGHT © CANON ELECTRONICS INC. 2018
1
(M3-bind head,
and
2
. And open the cable
5
CANON DR-G2140/G2110/G2090 FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
4) Remove 2 screws
using the short screwdriver and lift the
lower reading unit
out to the front, and then turn it to reverse.
Note: Do not pull it excessively because a ca-
ble is connected to the back side.
,
6
5) Remove 2 fitting parts
And then remove the cable band with
lock
3
and remove the connectors
. And remove the reading unit with
5
and
cables for the motor, grounding and sensor.
1
(M3, stepped 3.2)
3
slightly, and pull it
Figure 3-802
and the cover
1
.
2
4