Figure 8.
Installation on Combustible Flooring
1.
When unit is installed on a combustible floor, a
downflow combustible flooring base must be installed
between the furnace and the floor. The base must be
ordered separately. See Table 2 for opening size to
cut in floor.
The furnace and combustible flooring base shall not be
installed directly on carpeting, tile, or other combustible
material other than wood flooring.
CAT
Cabinet
Width
Number
B (17.5")
11M60
C (21")
11M61
Table 2. Combustible Flooring Base Opening Size
2.
After opening is cut, set the combustible flooring base
into opening.
3.
Check fiberglass strips on the combustible flooring
base to make sure they are properly glued and
positioned.
Page 8 of 73
CAUTION
Front to Rear
Side to Side
in.
mm
in.
22
559
18-3/4
22
559
22-3/4
4.
Lower supply air plenum into the combustible flooring
base until plenum flanges seal against fiberglass
strips.
NOTE: Be careful not to damage fiberglass strips.
Check for a tight seal.
5.
Set the furnace over the plenum.
6.
Ensure that the seal between the furnace and plenum
is adequate.
Installation on Cooling Coil Cabinet
NOTE: Downflow combustible flooring kit is not used.
1.
Refer to reverse-flow coil installation instructions for
correctly sized opening in floor and installation of
cabinet.
mm
2.
When cooling cabinet is in place, set and secure the
467
furnace according to the instructions that are provided
with the cooling coil. Secure the furnace to the cabinet.
578
3.
Seal the cabinet and check for air leaks.