Repair Parts List; Integrated Control Diagnostic Codes - Lennox Allied Air Enterprise A97DSMV Installation Instructions Manual

Warm air gas furnace downflow air discharge direct vent
Table of Contents

Advertisement

Repair Parts List

The following repair parts are available through Allied Air distributors. When ordering parts, include the complete furnace
model number listed on the nameplate. All service must be performed by a licensed professional installer (or equivalent),
service agency, or gas supplier.
Cabinet Parts
Heating Compartment Access Panel
Blower Access Panel
Top Cap
Control Panel Parts
Transformer
Integrated Control Board
Door Interlock Switch
Circuit Breaker
Blower Parts
Blower Wheel
Motor
Motor Mounting Frame
Blower Housing Cut Off Plate
Power Choke (1 HP only)

Integrated Control Diagnostic Codes

Press the diagnostic push button and hold it to cycle
through a menu of options. Every five seconds a new
menu item will be displayed.
Release the button when the desired mode is displayed.
When a solid "P" is displayed, the furnace capacity/ size is
programmed.
Code
Diagnostic Codes / Status of Equipment
Idle mode (Decimal blinks at 1 Hertz - 0.5 seconds ON, 0.5
seconds OFF).
Cubic feet per minute (cfm) setting for indoor blower (1 second
A
ON, 0.5 seconds OFF) / cfm setting for current mode displayed.
Cooling stage (1 second ON, 0.5 seconds OFF) / 1 or 2
C
displayed / Pause / cfm setting displayed / Pause / Repeat
codes.
Dehumidification mode (1 second ON, 1 second OFF) / cfm
d
setting displayed / Pause / Repeat codes.
Heat pump stage (1 second ON, 0.5 seconds OFF) / % of input
h
rate displayed / Pause / cfm setting / Pause / Repeat codes.
Gas Heat stage (1 second ON, 0.5 seconds OFF) / 1 or 2
H
displayed / Pause / cfm setting displayed / Pause / Repeat
codes. Blinking during ignition.
dF
Defrost mode.
Page 58 of 73
Heating Parts
Flame Sensor
Heat Exchanger Assembly
Gas Manifold
Combustion Air Inducer
Gas Valve
Main Burner Cluster
Main Burner Orifices
Pressure Switch
Ignitor
Primary Limit Control
Flame Rollout Switches
When the solid "E" is displayed, the control enters the Error
Code Recall mode. Error Code Recall mode menu options:
No change (displaying error history) remains in Error Code
Recall mode; solid "b" exits Error Code Recall mode; and
solid "c" clears the error history. Must press button while
flashing "c" is displayed to clear error codes.
When the solid "-" is displayed, the control enters the Field
Test mode. Field Test mode menu options: Solid "C" starts
pressure switch calibration; blinking "-" exits Field Test
mode.
Action Required to Clear and Recover