Specifications; Standard Accessories - Panasonic BM-ED500 Operating Instructions Manual

Panasonic bm-ed500 controller: user guide
Hide thumbs Also See for BM-ED500:
Table of Contents

Advertisement

SPECIFICATIONS

General
Power source:
Power consumption:
Ambient operating temperature:
Ambient operating humidity:
Dimensions:
Weight:
Input/Output/Interface
Iris camera interface:
Camera power output:
Ethernet port:
Electric lock interface:
Wiegand interface:
RS-485 interface:
Alarm output:

STANDARD ACCESSORIES

Operating instructions (This document)* ........................................... 1 pc.
Key* ................................................................................................... 2 pcs.
The following parts are used during installation procedures.
Mounting bracket .............................................................................. 1 pc.
Mounting screw (M4) ......................................................................... 2 pcs.
Ferrite core......................................................................................... 2 pcs.
Clamping tools .................................................................................. 5 pcs.
Bushing .............................................................................................. 2 pcs.
* You will use this item for installation. Keep it in a safe place after use.
120 V AC, 2.4 A, 60 Hz
190 W
150 W (when standby)
230 W (max. when operating)
0 °C to +40 °C {32 °F to 104 °F}
30 % to 80 % (relative humidity)
380 mm (W) x 410 mm (H) x 90 mm (D)
{15 in. (W) x 16-1/10 in. (H) x 3-1/2 in. (D)}
9.5 kg {21 lbs.}
Exclusive control, BNC x 3
32 V DC, 3 A, terminal x 2
10 Base-T/100 Base-TX, RJ-45 x 1
Solenoid operation output (24 V DC, 300 mA or less) x 1
Door-opening detector input (contact signal, 24 V DC, 100 mA or less) x 1
Locking/Unlocking detector input (contact signal, 24 V DC, 100 mA or less) x 1
Emergency unlocking activation input (contact signal, 24 V DC, 100 mA or less) x 1
Output x 2
5 V TTL level (25 mA or less)
Data Length 26 - 128 bit
Pulse Width Time 30/40 µs
Pulse Interval Time 1/2 ms
Output x 1
Baud Rate 2400/4800/9600/19200/38400
Parity none/odd/even
Stop Bits 1/2 bit
Data Bits 7/8 bit
Open collector x 8,
200 ms to 25.5 s,
Normally open or normally closed selectable
(Configurable through the administration PC, 24 V DC, 100 mA or less)
27