Power Board - Panasonic BM-ED500 Operating Instructions Manual

Panasonic bm-ed500 controller: user guide
Hide thumbs Also See for BM-ED500:
Table of Contents

Advertisement

G Input/Output Board
GATE 1
q
GATE 2
ALARM IN
w
G 8
G 7
ALARM OUT
CAMERA 3
CAMERA 2
CAMERA 1
CN904
q Gate control I/F connectors
An electric lock is connectable to the GATE 1 connec-
tor.
Wiegand/RS-485 Interface is connectable to the GATE
2 connector.
Note: When using Wiegand/RS-485 interface, refer to
UL Listed access control panel's installation instruc-
tions for compatibility information with iris camera
model BM-ET500 and control unit model BM-
ED500.
w Alarm input/output connectors
(ALARM IN, ALARM OUT)
ALARM IN: These connectors are not used.
ALARM OUT: These are connectors to output the alarm
signal from the control unit to the external devices.
Alarm-related parameters are configurable through
the administration PC. (Refer to the installation
guide of the administration software.)
e Iris camera connectors (CAMERA 1 to 3)
These are connectors for communication between iris
cameras and the control unit. Up to 3 iris cameras are
connectable (x 2 for recognition cameras and x 1 for an
enrollment camera).
r LAN connector (10Base-T/100Base-TX)
This is a port to connect the control unit to LAN (Local
Area Network).
Note: Route all power limited wiring away from non-
power limited wiring.
12
CN906
CN905
CN903
CN901
E901
9
8
7
6
5
4
3
2
1
E902
10BASE-T/
100BASE-TX
G 6
G 5
G 4
G 3
G 2
G 1
e
G Power board
r
q
w
q Camera power connectors (Power-limited terminal)
These are connectors to supply iris cameras with 32 V
DC power. One connector can supply power to one
camera.
Note: Power supply from one connector to more than
one camera may cause trouble.
w Power input connectors (Power-limited terminal)
Route away from all other power limited wirings. (Refer
to p.17.)
e Power switch
Turns on/off the power of the control unit. When
pressed, the power is on.
When the power is turned on, the power indicator lights
up and 32 V DC power is supplied from the camera
power connectors to iris cameras.
Note: Do not turn off the power during setting/initializa-
tion.
E10
DC-OUT
+32V
IC11
IC13
C34
0V
E10
C32
+32V
L25
0V
C31
D21
L23
E2
F1
E1
T6,3AL 250V
SW1
e
IC12
L29
CN1

Advertisement