Panasonic BM-ED500 Operating Instructions Manual

Control unit
Hide thumbs Also See for BM-ED500:

Advertisement

Control Unit

Operating Instructions

BM-ED500
Model No.
Before attempting to connect or operate this product,
please read these instructions carefully and save this manual for future use.

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic BM-ED500

  • Page 1: Control Unit

    Control Unit Operating Instructions BM-ED500 Model No. Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use.
  • Page 2 The lightning flash with arrowhead symbol, cover is obtained. within an equilateral triangle, is intended to A replacement fuse cover can be purchased from your local Panasonic alert the user to the presence of uninsulated Dealer. "dangerous voltage" within the product's...
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 8) Do not use near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  • Page 4: Table Of Contents

    CONTENTS IMPORTANT SAFETY INSTRUCTIONS ............................3 PREFACE ...................................... 5 FEATURE ...................................... 5 PRECAUTIONS ..................................... 6 DOCUMENT CONVENTION ................................. 7 MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ...................... 8 External View ..................................8 Internal View ..................................8 INSTALLATIONS AND SETTINGS ..............................11 INSTALLATIONS ..................................
  • Page 5: Preface

    PREFACE This system is designed for an iris physical access system, which identifies the person with one’s iris data. FEATURE This system is composed of an iris camera, control unit, and the administration PC (you need Administration Software BM-ES500E, an additional system component). In combination with electric locks, you can provide a com- plete iris-enabled physical access system for a single door.
  • Page 6: Precautions

    PRECAUTIONS • Refer all work related to the installation of this entrance will be unavailable. product to qualified service personnel or system • Replacement part installers. Exchange the following parts for the same type. Consult an expert on the load bearing capacity of the F1: K5D632AQ0001 F101: K5D122AQ0001 installation surface and structure.
  • Page 7: Document Convention

    DOCUMENT CONVENTION These operating instructions use the following convention when describing the use and operation of this system. Control unit (or this unit): Panasonic Control Unit BM-ED500 Iris camera: Panasonic Iris Camera BM-ET500E Administration software: Panasonic Administration Software BM-ES500E Caution: Text with this appearance is a special instruction which you should heed for your safety.
  • Page 8: Major Operating Controls And Their Functions

    MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS External View Internal View Fixing screws POWER ALARM S3 DC-OUT +32V IC11 IC13 IC12 POWER ALARM S3 – – +32V RESET – IC102 CN503 CN504 E101 E102 CN906 CN905 CN903 CN901 GATE 1 E901 GATE 2 10BASE-T/ 100BASE-TX...
  • Page 9 Setting board i Setting switches 1 (DSW 1) These switches are reserved for service. Notes: • Do not change the positions of these switches. Error may occur. • Keep hands away from these switches except for ser- POWER ALARM S3 vice personnel.
  • Page 10 Input/Output Board Power board CN906 CN905 CN903 CN901 E901 GATE 1 DC-OUT +32V IC11 IC13 IC12 E902 GATE 2 10BASE-T/ 100BASE-TX – ALARM IN +32V – ALARM OUT CAMERA 3 CAMERA 2 CAMERA 1 CN904 q Electric lock connectors An electric lock is connectable to GATE 1. Note: GATE 2 is not usable.
  • Page 11: Installations And Settings

    • This unit is for indoor use only. System Instruction (Maximum System) Coaxial cable(BNC) Coaxial cable(BNC) Camera power cable BM-ET500E (For identification) BM-ET500E (For enrollment) General-purpose BM-ED500 power supply (24V DC,UL listed) POWER ALARM S3 Camera 1 Electric lock* Camera 3 Administration PC* Camera 2 BM-ET500E...
  • Page 12: Preparation

    Preparation Prepare the following items before the installation. The necessary items and their lengths differ depending on condition. Preparing the necessary items Item number/Recommended type Item DC power cable Necessary when supplying DC power UL style 1015 or equivalents from the control unit to iris cameras (resistance of both ends: 0.03 /m or less) Maximum distance: 20 m...
  • Page 13: Installation

    Installation The following is the procedure to mount the control unit over the wall with the supplied mounting bracket. When mounting, follow the procedure. After mounting the plate, secure the control unit to the mounting plate. Otherwise, it may drop and cause damage or injury. Caution: This system must be installed within the protected promise in accordance with the International Electrotechnical Commission, and the local authorities having jurisdiction.
  • Page 14 2. Pass the power cable through the upper cable holes, and then mount the control unit over the wall. Make two holes to attach a flexible metal conduit. Use a metal conduit. Cable holes Use a metal conduit. Note: Use metal conduits when designated by the electrical regulation. 3.
  • Page 15 4. If you make the control unit output alarm signals to external devices and relate them to the alarm signals from the iris cam- eras or the control unit, connect the devices to ALARM OUT 1 to 8. For example, you can start alarm-related recording by connecting ALARM OUT and a recorder’s alarm input connector.
  • Page 16: Settings

    SETTINGS Operation Mode Setting The control unit has four operation modes. They are config- Description urable with 1 to 3 of the operation mode switches. (The fac- To use the control unit, the following settings are necessary tory default setting is shown in the figure.) with the setting switches or numeric buttons on the setting board.
  • Page 17 IP address/Subnet mask/Gateway Note: Before turning on the power again, change the operation mode switch to recognition or enrollment address setting mode. The following are the factory default settings of IP address and default gateway address. IP address/Subnet mask/Gateway IP address: 172.27.1.2 address confirmation Subnet mask: 255.255.255.0 Gateway address: 172.27.1.254...
  • Page 18 Electric lock Setting You can set the lock existence or types of electric locks with DSW 2. Electric lock 1: An electric lock which is connected to GATE 1. The factory default setting is shown in the figure. DSW 2 POWER ALARM S3 —...
  • Page 19: Operating Procedures

    OPERATING PROCEDURES Turning the Power On Turning the Power Off Power switch is inside the control unit. To turn the power 1. To turn the power off, open the door with the supplied on, open the door with the supplied key, and then press the key.
  • Page 20: When The Door Trouble Is Automatically Unrecoverable

    When the Door Trouble is When the Door Trouble is Automatically Unrecoverable Unrecoverable When trouble has occurred to the door and it is automati- When trouble has occurred to the door and it is unrecover- cally unrecoverable, ALARM and S3 light up to inform you able, all the indicators (POWER, ALARM, and S1 to S3) light of the trouble status.
  • Page 21: Appendix

    APPENDIX ADDITIONAL SYSTEM COMPONENTS Iris Camera BM-ET500E Administration Software BM- ES500E ACCEPT REJECT READY This product is necessary to administer iris data, IDs, and passwords. Administration Software BM-ES500E This product is used for recognition/enrollment of iris data. ID-and-password authorization is also available.
  • Page 22: Specifications Of Electrical Lock Connectors (Gate 1)

    SPECIFICATIONS OF ELECTRICAL LOCK CONNECTORS (GATE 1) Port No. Signal Description Remarks Lock control Solenoid SW Activated 300 mA or less Lock control ground Solenoid SW Activated Gate status Reed SW Activated Gate status ground Reed SW Activated Lock status (locking) Micro SW Activated Lock status (unlocking) Micro SW Activated...
  • Page 23: Specification Of Alarm Output Connectors (Alarm Out)

    SPECIFICATION OF ALARM OUTPUT CONNECTORS (ALARM OUT) Port No. Signal Name Signal Description Remarks OUT1 Alarm output 1 (+) Open-collector output Ground OUT1 ground Alarm output 1 (–) Open-collector output OUT2 Alarm output 2 (+) Open-collector output Ground OUT2 ground Alarm output 2 (–) Open-collector output OUT3...
  • Page 24: Troubleshooting

    TROUBLESHOOTING Check the following before requesting repair. If a trouble cannot be corrected even after checking and trying remedy, contact your dealer. Problem Check item Remedy POWER does not light up. AC power cord may be disconnected Connect the power cord to the power from the control unit's power input con- input connector.
  • Page 25: Specifications

    SPECIFICATIONS General Power Source: 100 to 120 V/220 to 240 V AC, 2.4 A/1.2 A, 50/60 Hz Power Consumption: 190 W 150 W (when standby) 230 W (max. when operating) Ambient Operating Temperature: 0 °C to +40 °C (32 °F to 104 °F) Ambient Operating Humidity: 30 % to 80 % Dimensions:...
  • Page 26 Matsushita Electric Industrial Co., Ltd. Web Site : http://www.panasonic.co.jp/global/ NM1002-1122 3TR001104BAA Printed in Japan Gedruckt in Japan Imprimé au Japon Impreso en Japón Stampat in Jiappone 2002 © Matsushita Electric Industrial Co., Ltd. All rights reserved.