7.2.4

Altitude

Altitude, air pressure, and ambient temperature influence the thermal operation
of the components described in this document. They have been developed and
tested at ~500 m (1,640 ft) above sea level at a typical ambient temperature of
20°C (68 °F). Because of only marginal variations within a limited range of
altitudes, this product operates as specified within altitudes from sea level to
2,000 m (6,560 ft), depending on the level. This is with reference to temperature
ranges of air-cooled versions.
Note:
Emerson can assist the user in planning operation outside this altitude range upon request.
Maximum altitude for the RXi2–EP IPC is specified in the following table.
Table 7-5
Item
Maximum Altitude
Operating
Storage
7.2.5

Regulations and Certification

Table 7-6
Item
EMC
Product Safety
UKCA
Figure 7-1
Specifications
Maximum Altitude
Level A
2 km (6,560 ft)
12 km (39,370 ft)
Regulations and Certification
Specification
EMC Directive 2014/30/EU
EN 61000-6-4 Emission standard for industrial environments
EN 61000-6-2 Immunity standard for industrial environments
FCC Part 15 B
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
CAN ICES-3 (A)/NMB-3(A)
LVD Directive 2014/35/EU
IEC 62368-1 2
Edition
nd
UL 62368-1 (UL file number E214940)
Emerson Process Management Shared Service Ltd
Meridan East, Meridan Business Park, Leicester LE19 1UX United
Kingdom
RXi2-EP Data Nameplate