Misfeed Detection Timing And Troubleshooting Procedures; Paper Take-Up/Transport Misfeed - Konica Minolta Di1610 Service Manual

Hide thumbs Also See for Di1610:
Table of Contents

Advertisement

2-4.

Misfeed Detection Timing and Troubleshooting Procedures

(1)

Paper Take-Up/Transport Misfeed

<Detection Timing>
Type
MP tray Pick-
up Jam
2nd tray Pick-
The Paper Take-Up Switch does not turn on after the predetermined period
up Jam
of time has elapsed after paper take-up began.
Bypass tray
Pick-up Jam
The Exit Sensor is not blocked after the predetermined period of time has
Separator
elapsed after the Paper Take-Up Switch is turned on.
Jam
The Paper Take-Up Switch is not turned off after the predetermined period
of time has elapsed after the Paper Take-Up Switch is turned on.
<Troubleshooting Procedures>
Paper Take-Up Switch (S1)
Exit Sensor (PS1)
Paper Take-Up Solenoid (SL1)
Step
Action
1
Initial checks
2
SL1 solenoid check
3
S1 switch check
4
PS1 sensor check
5
Replace PWB-P.
Description
Relevant Electrical Parts
Controller/Mechanical Control Board (PWB-P)
Ref. Page
☞ T-6
☞ T-2
PWB-P MPJ3P-2
☞ T-2
☞ T-1
T-9
WIRING DIAGRAM
Location
Control Signal
(Electric Parts)
I-6 to 7
PWB-P
G-8 to 9
MPJ10P-2
PWB-P
E to F-7 to 8
MPJ8P-3