11 Measurements and Adjustments

This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in
Troubleshooting Guide (P.27)

11.1. Equipment Required

• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm)
Hewlett Packard, 53131A is recommended.
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
This equipment may be useful in order to precisely adjust like a mass production.

11.2. The Setting Method of JIG

<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: Refer to parts list of Fixtures
and Tools(P.99)

11.2.1. Connections (Base Unit)

1
Connect the AC adaptor.
Connect the JIG Cable GND (black).
2
3
Connect the JIG Cable RX (red) and TX (yellow).
UTX
URX
Note:
*: COM port names may vary depending on what your PC calls it.
UGND
Base unit P. C. board
KX-TGC210/KX-TGC212/KX-TGC213/KX-TGC220/KX-TGC222/KX-TGCA20
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E),
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
Resistor
R2
R3
R4
R7
JIG Cable
3
UTX (yellow)
2
UGND (black)
3
URX (red)
DC JACK
1
AC adaptor
51
change
the
following
Old value (k)
New value (k)
22
3.3
22
3.3
22
4.7
4.7
10
To Serial Port
(COM port 1*)
PC
values