KX-TGC210/KX-TGC212/KX-TGC213/KX-TGC220/KX-TGC222/KX-TGCA20
Items
(N)
Audio Check and
Confirmation
(O) SP phone Audio Check
and Confirmation
(P)
Charge Pump 3.0 V
Supply Confirmation
(Q)
Charge Pump CP4V
Supply Confirmation
Check
Point
-
1. Link to BASE which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 50 mA.
3. Input -45 dBm (600 )/1 kHz to MIC of Handset. Measure the Level at Line I/F
and distortion level.
4. Confirm that the level is -1.5 ± 5 dBm (for BL,TU,BX,UE) or -0.4 ± 5dBm (for
CX) or -4.0 ± 5dBm (for HK,TW) or -3.5 ± 5dBm (for ML) and that the distortion
level is < 5 %
5. Input -20 dBm (600 )/1 kHz to Line I/F. Measure the Level at Receiver of
Handset and distortion level (Receive volume set to second position from
minimum).
6. Confirm that the level is 13.0 ± 4 dBm (for BL,TU,BX,UE) or -25.0 ± 4 dBm (for
CX) or -22.0 ± 4 dBm (for HK,TW,ML) and that the distortion level is < 5 % at
Receiver (34 Load).
-
1. Link to Base which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 50 mA.
3. Set the handset off-hook using SP-Phone key.
4. Input -30 dBm (600 )/1 KHz to Line I/F and measure Receiving level at SP+
and SP-.
5. Confirm that the level is -10.0 dBm ± 3 dB and that the distortion level is < 5 %.
(vol = Max at SP (8 Load))
CP3V
1. Confirm that the voltage between testpoint CP3.0V and GND is 3.0 V ± 0.3 V. C30, C53, C29
CP4V
1. Confirm that the voltage between testpoint CP4V and GND is 4.0 V ± 0.3 V.
(Power is supplied when LED in on)
Procedure
at TEL Line (600 Load).
44
Check or
Replace Parts
IC1, C12, C11,
C13, MIC,
R23, R24,
R25, RA4,
C70, C71
IC1, C78, C79,
R76, R77
C52, C55,
C30, C29