KX-TGC210/KX-TGC212/KX-TGC213/KX-TGC220/KX-TGC222/KX-TGCA20
Frequently Used Items (Base Unit)
ex.)
Items
C-ID (FSK) sensitivity
C-ID (DTMF) sensitivity
Frequency
ID
Bell length
PULSE Dial speed
(10PPs->20PPs)
Note:
(*1) When you enter the address or New Data, please refer to the table below.
Desired Number (hex)
0
1
.
.
.
9
(*2)
Bell length
PULSE Dial speed
(10PPS -> 20PPS)
Address
Default Data
08 6A/08 69
00/28
08 86/08 85
08/00
00 08 / 00 07
01/00
00 02 ~ 00 06
Given value
03 C6
32 (5 sec)
(*2)(for
BL,HK,TU,TW,
ML)
64 (10 sec)
(*2)(for
CX,BX,UE)
03A0
28 (40msec)
(*2)
(for
CX,BX,UE)
21
(33msec)(*2)
(for
HK,TW,ML)
2A (40msec)
(*2)
(for TU)
03 A1
3C (60 msec)
(*2)
(for
CX,BX,UE)
43 (67 msec)
(*2)(for
HK,TW,ML)
3A
(60 msec) (*2)
(for TU)
03 B5
57 (870 msec)
(*2)
Input Keys
0
1
.
.
.
9
32 (hex) = 50 (dec)  50  100 msec = 5000 msec (5 sec)(for BL,HK,TU,TW,ML)
64 (hex) = 100 (dec)  100  100 msec = 10000 msec (10 sec)(for CX,BX,UE)
28 (hex) = 40 (dec)  40  1 msec = 40 msec (for CX,BX,UE)
21 (hex) = 33 (dec)  33  1 msec = 33 msec (for HK,TW,ML)
2A (hex) = 42 (dec)  (42-2)  1 msec = 40 msec (for TU)
3C (hex) = 60 (dec)  60  1 msec = 60 msec (for CX,BX,UE )
43 (hex) = 67 (dec)  67  1 msec = 67 msec (for HK,TW,ML )
3A (hex) = 58 (dec)  (58+2)  10 msec = 60 msec (for TU)
57 (hex) = 87 (dec)  87  10 msec = 870 msec
New Data
00/1C
00/14
(3 dB up)
(6 dB up)
0B/4C
0F/F6
(3 dB up)
(6 dB up)
-
-
-
-
1E (3 sec)
14 (2 sec)
1E (3 sec)
14 (2 sec)
14 (20 msec)
-
14 (20 msec)
-
14 (20 msec)
-
1F (30 msec)
-
1F (30 msec)
-
1F (30 msec)
-
2C (440 msec)
-
Desired Number (hex)
A
B
C
D
E
F
22
Remarks
When hex changes from "00/28" to "00/1C" or
"00/14", gain increases by 3 dB or 6 dB.
When hex changes from "00/01" to "0B/4C" or
"0F/F6", gain increases by 3 dB or 6 dB.
Use these items in a READ-ONLY mode to
confirm the contents. Careless rewriting may
cause serious damage to the computer system.
This is time until bell stops ringing.
(Unit: 100 msec)
This is time until bell stops ringing.
(Unit: 100 msec)
This is pulse make time. (Unit:1msec)
This is pulse break time. (Unit:1msec)
This is pulse break time. (Unit:1msec)
This is pulse break time. (Unit:1msec)
This is pulse break time. (Unit:1msec)
This is pulse break time. (Unit:1msec)
This is inter-digit time in pulse mode. (Unit:10
msec)
Input Keys
[Flash] + 0
[Flash] + 1
[Flash] + 2
[Flash] + 3
[Flash] + 4
[Flash] + 5