Remote Annex Quick Start for Windows
166-024-858
12
2.
Modify the following parameters in the external CSU
through its front panel:
FORMAT (FDL) = ANSI (or ATT)
CLOCK = SLAVE
DISTANCE = 133 ft.
3.
Use na to enable SNMP sets, modify the PRI parameter
switch_type if it is other than 5ess (NI-2 or DMS100, for
example) and to specify the distance between the Remote
Annex 6300 and the CSU.
% na
command: annex 129.9.200.62
command: set annex allow snmp sets y
command: set pri switch_type dms
command: set pri dsx1_line_length 101-135
command: boot
command: quit

Setting Up PRI Channels

To configure PRI channels using Quick2Config Annex:
1.
Click on the Quick2Config icon to open the application.
2.
Choose File > Add Annex, enter the name or IP address of
the Remote Annex in the Add Annex dialog box, and click
on
.
OK
Quick2Config Annex lists the Annex in the tree view on the left
side of the window.
3.
Click on the Annex in the tree view.
Quick2Config Annex displays a set of tab windows on the right
for configuring the selected Annex.
4.
Choose Config > Edit Configuration File to modify Session
Parameter Blocks.