Figure 6 : Minimum distance of portables to Base Stations
user's office
Installing multiple Base Stations in a cell center
In cases where there is more than one Base Station at a cell center, follow these
guidelines:
•
Position all of the Base Stations on the same surface with matching
composition.
•
Allow a clearance of at least 3
and surrounding objects.
•
Do not position more than four Base Stations in a single cell.
For CT2Plus protocol
•
Position all the Base Stations that are at the same cell center no more
than 5 ft (1.5 m) and no less than 3
•
Position the Base Stations on a ceiling as shown in Figure 7.
For PCI protocol
•
Position the Base Stations as close together as possible but maintain a
minimum distance of 54 in. (1.35 m) apart (center to center) at the same
cell center.
•
Do not mount Base Stations in rows.
Base Station location Page 11 of 102
Northern
Telecom
Northern
Telecom
Northern
Telecom
Northern
Telecom
80 in. (2.0 m) minimum
1
/
in. (9 cm) between the Base Stations
2
1
/
in. (9 cm) from each other.
2
Meridian Companion Site Planning Reference Manual