Using the appropriate table in your Companion installation documentation,
you determine that one Companion system cannot serve 300 users with 63
Base Stations. You require a minimum of three systems where:
system 1 covers cells 1C9, 1C10, 1C11, 1C12, 1C13 and 1C14, with 89
users and 19 Base Stations
system 2 covers cells 1C1, 1C8, 1C15, 1C16, 1C17 and 1C18, with 101
users and 22 Base Stations
system 3 covers cells 1C2, 1C3, 1C4, 1C5, 1C6 and 1C7 with 110 users
and 22 Base Stations
Figure 32 shows the floor plan of the Apex Department Store with the multiple
systems.
Figure 32 : Restricted mobility example
1C13
1C10
system 1
1C11
1C9
cell center
system boundary
Apex Department Store's coverage requirements
none of the systems overlap
each cell uses only one system
all of the users in the same cell are on the same system
each call that comes into the Apex Department Store searches only for a
portable on one of the three systems
1C15
1C14
1C17
1C12
Meridian Companion Site Planning Reference Manual
Planning complex sites Page 73 of 102
1C1
system 2
1C16
1C8
1C7
1C18
system 3
1C3
1C2
1C5
1C6
1C4