Emptying The Water Tank - Prem-I-Air EH1934 Instruction Manual

20 litre / day dehumidifier
Table of Contents

Advertisement

starts working after 3 seconds.
When room humidity ≤ set humidity -3%, the compressor stops working and the fan will shut down after
a short 30s delay.
Both fan speed and humidity can be adjusted under auto mode.
● Continuously drying mode:
● Sleep mode:
is automatically switched from high to low. Touch any button to wake up the display. Touch sleep button
again to exit the sleep mode. When humidity level ≤ 57%, the compressor stops and the fan will shut
down after 30s. When the humidity ≥ 63% the fan starts then the compressor after 3s.
In sleep mode the fan speed and humidity cannot be modified.
Humidity
In auto mode you can use these buttons to adjust the set humidity: every time you press the add will
increase by 5%, the minus will decrease by 5%. The humidity can range from a minimum of 30% to a
maximum of 80%.
Timer
Press this key to set the timer function of 0-24 hours.
or minus buttons, the value increases/decreases by 1 hour and then the corresponding timing value is
displayed on the screen. Set the value to "00" to cancel the timer function and the timer indicator will
turn off.
After the timer is set and completed, the timer LED is on during the timing period. After the timing
period the timer LED turns off automatically.
In the running state, set the time to turn off the machine.
in the standby state, set the time to turn on the machine.
Fan Speed
The fan speed can only be adjusted in the automatic mode. Press this key to switch between the high
and low
fan speeds. The corresponding fan speed indicator lights
Child Lock
A long press this button to operate the child lock function. The child lock indicator lights. All the keys are
locked and cannot be operated. Press this button again, the indicator light will go out, and the button
operation will be restored.
Shutdown or power off will automatically cancel the child lock function.
5. DRAINAGE

EMPTYING THE WATER TANK

The machine continues to run, but the humidity cannot be adjusted.
After no operation in 10 seconds, all indicators gradually darken, and the fan speed
The interval is 1 hour. Each time you press the add