When the tank is full, The unit will make a buzzing sound, and the "Water Full"
light will turn on.
⚫ Press the POWER button to turn off the unit.
⚫ Pull on the water tank and simply slide out of the body of the
dehumidifier.
⚫ Empty the water into an area with a drain or outside.
⚫ Clean the inside of the tank as well as the outside.
⚫ Replace the empty tank back into the unit.
⚫ Press the POWER button to resume operating.
⚫ If the Water Full light does not extinguish, check that the float is correctly in place.
Warning
1. Do not discard water tank magnets and plastic rivets. Otherwise, the machine will not automatically
stop when the water tank is full, and the condensed water will overflow.
2. If the water tank is dirty, rinse with clean water. Avoid using detergents or other solvents as this may
cause the water tank to be damaged and leak
3.
Replace the empty tank back into the unit.
the machine cannot restart.

CONTINUOUS DRAINING

For continuous operation or unattended dehumidification, please connect the
drain hose to the unit. Condensate water can automatically drip into a bucket or
drain by gravity.
1. Straighten the drainage pipe
2. Insert one end of the drain pipe into the drain hole and place the other end
into the bucket, container, or drain.
Warning
1. Please do not block the drain or drainpipe, if the pipe is blocked the
condensed water will flow into the water tank.
2. Please do not bend the drainpipe. The height of the drainpipe should be lower
than the outlet.
3. The drainpipe should be securely connected to the outlet.
4. Do not submerge the end of the drain hose as this can cause an 'air lock' in the
hose and prevent the water from draining.
Otherwise, the water full indicator may remain red, and

Advertisement