Prem-I-Air EH1384 Manual

Prem-I-Air EH1384 Manual

Light commercial dehumidifier, 50 litres per day moisture removal capacity, electronic humidistat control, washable air filter, robust steel case

Advertisement

EH1384
Light Commercial Dehumidifier
50 litres per day moisture removal capacity
Electronic humidistat control
Washable air filter
Robust steel case
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Prem-I-Air EH1384

  • Page 1 EH1384 Light Commercial Dehumidifier 50 litres per day moisture removal capacity Electronic humidistat control Washable air filter Robust steel case Page 1...
  • Page 2: Before Use

    IMPORTANT Installer and Users please note: These instructions should be read carefully and left with the user of the product for future reference. BEFORE USE You must inspect the product including its cable and plug for any signs of damage. If the product is damaged, DO NOT use it, and contact your supplier immediately.
  • Page 3 • Switch the appliance on at the mains socket. Then press the power ON/OFF button to turn the unit ON. The appliance will wait for 3 minutes whilst the refrigerant settles before starting to operate, this is to extend the life of the compressor.
  • Page 4: Emptying The Collected Water

    EMPTYING THE COLLECTED WATER • If not using a drainage hose, empty the bucket when the display shows "E4" and the water full indicator lights up. • Open the lower front door. • Pull the bucket outwards • Empty the water down a drain. STORAGE If the appliance is not going to be used for a long time: 1.
  • Page 5: Pat Testing

    • Do not leave the product unattended for long periods of time. • Ensure that the product does not tip over whilst there is water in the bucket. OPERATING COSTS At time of going to press, the average cost of electricity is £0.13 per unit (kilowatt-hour).
  • Page 6: Maintenance

    MAINTENANCE • Before cleaning, turn the appliance off, and disconnect from the mains supply. The appliance may then be cleaned using a damp cloth with a drop of washing-up liquid to remove any dust or dirt from the case. Do no use stronger detergents or solvents as these may damage the surface finish.
  • Page 7 Push the filter upwards, until it fits in place, with the wide web resting on the top of the water container. • If the mains lead is damaged, it must be replaced by the manufacturer or an authorised service centre. If the mains plug needs to be replaced, proceed as follows: •...
  • Page 8: Fault Finding

    FAULT FINDING Appliance does not operate when switched on: • There is a 3 minute delay before the compressor starts. This is to protect the compressor. Appliance stops operating and “E4” is displayed on panel along with the "TANK FULL" indicator lights. •...
  • Page 9: Technical Specification

    TECHNICAL SPECIFICATION Dimensions: 322×452×592 mm Weight: 30 kg Power supply: 230 V ~ 50 Hz Power consumption: 900 W Operating current: 4.2 A Refrigerant: R407c Refrigerant load: 370 g Discharge pressure: 2.5 MPa Suction pressure: 1.0 MPa Sealing: hermetically sealed Airflow: 350 m Moisture removal:...
  • Page 10: Service / Warranty

    SERVICE WARRANTY Prem-i-Air guarantees the product free from defects in materials and workmanship for a period of twelve months. Should this appliance be operated under conditions other than those recommended, at voltages other than the voltage indicated on the appliance, or any attempts made to service or modify the appliance, then the warranty will be rendered void.

Table of Contents