Configuring Qos Policies; Qos Policy Command; Nortel Ethernet Routing Switch 4500 Series - Nortel 4524GT Configuration

Ethernet routing switch 4500 series
Hide thumbs Also See for 4524GT:
Table of Contents

Advertisement

70 Chapter 2 Configuring Quality of Service (QoS) with the CLI
Configuring QoS Policies
QoS policies can be configured using the following CLI commands.

qos policy command

The qos policy command creates a QoS policy.
The syntax for the qos policy command is
qos policy <1-55000>
[port <port_list>] if-group <WORD>
| block} {clfr-id
{{in-profile-action
<WORD>} | meter
precedence <1-8>
aggregate>]} [session-id <1-4294967295>]
"qos policy parameters" (page 70)
command.
qos policy parameters
Parameter
<1-55000>
[enable | disable]
name <WORD>
port <port_list>
if-group <WORD>
clfr-type <classifier | block>
clfr-id <1-55000>
clfr-name <WORD>
in-profile-action <1-55000>
in-profile-action-name
<WORD>
meter <1-55000>
Copyright © 2007, Nortel Networks
.
[enable | disable] [name
<1-55000>
<1-55000> | in-profile-action-name
<1-55000>
[track-statistics

Nortel Ethernet Routing Switch 4500 Series

Configuration — Quality of Service
NN47205-504 (322816-B)
5.1 23 November 2007
clfr-type {classifier
| clfr-name
| meter-name
<individual |
describes the parameters for this
Description
Enter an integer to specify the QoS policy;
range is 1 to 55000.
Enable or disable the QoS policy. Default is
disable.
Enter the name for the policy; maximum is 16
alphanumeric characters.
The ports to which to directly apply this policy.
Enter the interface group name to which this
policy applies; maximum number of characters
is 32 US-ASCII.The group name must begin
with a letter within the range a..z or A..Z.
Specify the classifier type; classifier or block.
Specify the classifier ID; range is 1 to 55000.
Specify the classifier name or classifier block
name; maximum is 16 alphanumeric characters.
Enter the action ID for in-profile traffic; range
is 1 to 55000.
Enter the action name for in-profile traffic;
maximum is 16 alphanumeric characters.
Enter meter ID associated with this policy;
range is 1 to 55000.
03.01 Standard
<WORD>]
<WORD>}
<WORD>}

Hide quick links:

Advertisement

Table of Contents
loading