Nortel 4500 Series Installation Manual

Nortel 4500 Series Installation Manual

Ethernet routing switch installation - sfps and xfps
Hide thumbs Also See for 4500 Series:
Table of Contents

Advertisement

Quick Links

Nortel Ethernet Routing Switch 4500 Series
Installation — SFPs and XFPs
Release: 5.2
Document Revision: 02.01
www.nortel.com
NN47205-301
324186-B
.

Advertisement

Table of Contents
loading

Summary of Contents for Nortel 4500 Series

  • Page 1 Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs Release: 5.2 Document Revision: 02.01 www.nortel.com NN47205-301 324186-B...
  • Page 2 While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice.
  • Page 3: Table Of Contents

    10 Gigabit small form factor pluggable transceivers Selecting an XFP 29 Job aid: XFP models 30 Installing an XFP 30 Removing an XFP 32 Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 4 General XFP specifications 48 10GBASE-SR XFP specifications 48 10GBASE-LRM XFP specifications 50 10GBASE-LR/LW XFP specifications 52 10GBASE-ZR/ZW XFP specifications 53 Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 5: New In This Release

    New in this release The following sections detail what’s new in Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs (NN47205-301) for Release 5.2. • “Features” (page 5) Features See the following sections for information about feature changes: New SFPs Release 5.2 supports four new SFPs.
  • Page 6 6 New in this release Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 7: Introduction

    “10 Gigabit small form factor pluggable transceivers” (page 29) • “SFP specifications” (page 35) • “XFP specifications” (page 47) Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 8 8 Introduction Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 9: Safety And Equipment Care Information

    The wrist strap should touch the skin and be grounded through a one megaohm resistor. • Do not touch anyone who is not grounded. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008...
  • Page 10: Care Of Fiber Optic Equipment

    Store unused fiber optic patch cables in a cabinet, on a cable rack, or flat on a shelf. Frequent overstressing of fiber optic cable causes progressive degeneration that leads to failure. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008...
  • Page 11: Fiber Optic Connector Care

    If you suspect only the possibility of dust particles (for example, which can occur when a connector is left uncapped in a clean environment), use high-quality canned air or a reel ceaner (for example, a Cletop) to Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright ©...
  • Page 12: Cleaning Single Connectors

    To avoid getting debris in your eyes, wear safety glasses when working with the canned air duster. To avoid eye irritation on contact, wear safety glasses when working with isopropyl alcohol. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008...
  • Page 13: Cleaning Duplex Connectors

    Compressed air must be free of dust, water and oil, or filmy deposits or scratches on the surface of the connector can result. • fiber optic microscope for inspecting connectors Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008...
  • Page 14: Cleaning Receptacles

    --End-- Cleaning receptacles Clean connector receptacles or ports so that the optical signal is minimally attenuated by the connection. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 15 If you are not reinstalling the connector, be sure to use a protective cap. If problems persist, ensure that the connector or receptacle are not damaged. --End-- Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 16: Product Safety Warnings And Information

    CUIDADO Risco de danos ao equipamento Para evitar danos com descarga eletrostática, sempre use uma pulseira antiestática que esteja conectada a uma tomada ESD. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008...
  • Page 17: Laser Safety Warnings

    Rischio di danni all’apparecchiatura Questo prodotto può essere installato solo da personale esperto. Laser safety warnings This section provides laser safety warnings. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 18 Nunca olhe para dentro da fibra ótica ou da porta do conector. Tenha sempre em mente que os cabos de fibra ótica estão ligados a uma fonte de luz. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright ©...
  • Page 19 Tenere sempre presente che i cavi a fibra ottica sono collegati a una sorgente luminosa. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008...
  • Page 20 20 Safety and equipment care information Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 21: Small Form Factor Pluggable Transceivers

    70 km, and 120 km. Determine the required media and connector type. Fiber optic cable is required for any reach over 100 m. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008...
  • Page 22: Job Aid: Sfps And Common Applications

    Job aid: SFP models without DDI support SFPs are hot-swappable input/output enhancement components designed for use with Nortel products to allow Gigabit Ethernet ports to link with other Gigabit Ethernet ports over various media types. Nortel Ethernet Routing Switch 4500 Series Installation —...
  • Page 23 1470 nm to 1610 nm, up to 40 km AA1419032-E5 1000BASE-ZX CWDM (LC) AA1419033-E5 to 1470 nm to 1610 nm, up to 70 km AA1419040-E5 Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 24: Job Aid: Sfp Models With Ddi Support

    Routing Switch 4500 that supports SFPs beginning with Release 5.2. The optical functions of the SFP are supported. Access to the DDI information will be provided in a future release. The following table lists and describes the Nortel SFP models with DDI capability. Table 3...
  • Page 25 SFP resists pressure, do not force it; turn it over, and reinsert it. Apply a light pressure to the device until it clicks and locks into position. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008...
  • Page 26: Job Aid: Locking And Extractor Mechanisms

    Figure 1 SFP with bail lock and extraction mechanism The following figure shows the 1000BASE-SX MT-RJ SFP. Push the tab to release the device. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008...
  • Page 27: Removing An Sfp

    Never look into an optical fiber or connector port. Always assume that fiber optic cables are connected to a light source. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008...
  • Page 28 ATTENTION If you discard the SFP, be sure to dispose of it according to all national laws and regulations. --End-- Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 29: Gigabit Small Form Factor Pluggable Transceivers

    Form Factor Pluggable (XFP) transceivers, and lists some technical specifications for the supported XFP models. ATTENTION Nortel recommends that you only use Nortel-qualified XFPs. If you do choose to use other vendor XFPs, be aware that Nortel does not support the use of other XFPs. Navigation •...
  • Page 30: Job Aid: Xfp Models

    Job aid: XFP models XFPs are hot-swappable input/output enhancement components designed for use with Nortel products to allow 10 Gigabit Ethernet ports to link with other 10 Gigabit Ethernet ports. All Nortel XFPs use Lucent connectors (LC) to provide precision keying and low interface losses.
  • Page 31 Insert the XFP into the XFP slot on the module. Apply a light pressure to the XFP until the device clicks and locks into position in the module. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright ©...
  • Page 32: Removing An Xfp

    Remove an XFP to replace it or to commission it elsewhere. For translations of the following messages, see “Product safety warnings and information” (page 16). Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 33: Nortel Ethernet Routing Switch 4500 Series Installation - Sfps And Xfps

    ATTENTION If you discard the XFP, be sure to dispose of it according to all national laws and regulations. --End-- Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 34 34 10 Gigabit small form factor pluggable transceivers Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 35: Sfp Specifications

    • “1000BASE-BX DDI SFP specifications” (page 44) SFP labels The Nortel label on a typical SFP contains a Nortel serial number, a bar code, a manufacturer’s code, an interface type, and a part number. Nortel Ethernet Routing Switch 4500 Series Installation —...
  • Page 36: General Sfp Specifications

    This device can be used with the Ethernet Routing Switch 4526FX, 4526T, 4526T-PWR, 4550T, 4550T-PWR, and 4524GT. The following table describes the T1 SFP specifications. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008...
  • Page 37 RJ-48C pinouts Description Receive ring Receive tip Receive shield Transmit ring Transmit tip Transmit shield Not used Not used Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 38 You can use a short crossover cable with a straight-through cable adapter to connect to a straight-through cable. Do this to convert a straight-through cable to a crossover cable. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright ©...
  • Page 39: T1 Sfp-Default Settings

    0 (normal operation) ATTENTION The T1 SFP module must be configured to match the parameters of the T1 equipment at the far end. If you must change the parameters, contact Nortel Technical Support. 1000BASE-T SFP specifications The 1000BASE-T SFP provides Gigabit Ethernet connectivity using a single eight-pin RJ-45 connector.
  • Page 40: 1000Base-Sx (Lc) Sfp Specifications

    Link optical power budget 7.0 deciBels (dB) Transmitter characteristics Launch power -10 to -4.0 deciBels referenced to 1 milliwatt (dBm) Receiver characteristics Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 41: 1000Base-Sx (Mt-Rj) Sfp Specifications

    The following table describes standards, connectors, cabling, and distance for the 1000BASE-LX SFP. Table 14 IEEE 802.3z 1000BASE-LX SFP specifications Parameter Specifications Connectors Duplex LC Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 42: 1000Base-Xd Cwdm Sfp Specifications

    0 to 60C Link optical power budget 17 dB Transmitter characteristics Launch power -4.0 to 1.0 dBm Receiver characteristics Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 43: 1000Base-Zx Cwdm Sfp Specifications

    Table 17 1000BASE-SX SFP DDI (550 m) specifications Parameter Specifications Maximum electrical power consumption 1 watt (W) Connector Duplex LC Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 44: 1000Base-Lx Ddi Sfp Specifications

    -3.0 dBm 1000BASE-BX DDI SFP specifications The 1000BASE-BX bidirectional SFPs (part numbers AA1419069-E6 and AA1419070-E6) provide Gigabit Ethernet connectivity over a single fiber. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 45 Maximum transmitter and dispersion power 3.3 dB penalty Transmitter characteristics Maximum launch power -3.0 dBm Minimum launch power -9.0 dBm Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 46 46 SFP specifications Parameter Specifications Receiver characteristics Maximum receiver sensitivity -19.5 dBm Maximum input power (maximum average -3.0 dBm receive power) Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 47: Xfp Specifications

    All Nortel XFPs meet or exceed these standards. ATTENTION Nortel recommends that you only use Nortel-qualified XFPs. If you do choose to use other vendor XFPs, be aware that Nortel does not support the use of other XFPs. Navigation •...
  • Page 48: General Xfp Specifications

    Risk of equipment damage To prevent damage to the optical receiver, ensure that at least 1 dB of attenuation is present between the transmit and receive ports. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008...
  • Page 49 -12 dB Stressed receiver sensitivity in OMA -7.5 dBm Receiver electrical 3 dB upper cutoff 12.3 gigaHertz (GHz) frequency Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 50: 10Gbase-Lrm Xfp Specifications

    50 XFP specifications The stressed sensitivity values are for system level BER measurements, which include the effects of CDR circuits. Nortel recommends that you allocate at least 0.4 dB additional margin if you make component level measurements without the effect of CDR circuits.
  • Page 51 Electrotechnical Commission, and OFL denotes Over Filled Launch. The following table is also based on the 802.3aq standard and specifies the measurement conditions for each fiber type. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright ©...
  • Page 52: 10Gbase-Lr/Lw Xfp Specifications

    Minimum launch power in OMA minus -6.2 dBm transmission and dispersion penalty (TDP) Minimum optical modulation amplitude -5.2 dBm Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 53: 10Gbase-Zr/Zw Xfp Specifications

    Risk of BER increase For proper XFP operation, ensure that at least 11 dB of attenuation is present between the transmit and receive ports. Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008...
  • Page 54 Maximum receive power (for BER 10 and 9 -7.0 dBm dB ER) Maximum average receive power for damage 5.0 dBm Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 55 10GBASE-ZR/ZW XFP specifications 55 Parameter Specifications Receiver reflectance (maximum) -27 dB Receive electrical 3 dB upper cutoff frequency 9.3 GHz Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 56 56 XFP specifications Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 57 XFP 30, 53 dispersion compensation 50 802.3aq-2006 50 duplex connectors cleaning 13 AA1403001-E5 30, 52 AA1403005-E5 30, 48 electrostatic discharge 9 Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 58 SFP 22, 24, 36 installation 30 label 47 lock and extraction mechanisms 32 physical specifications 48 removal 32 selection 29 Nortel Ethernet Routing Switch 4500 Series Installation — SFPs and XFPs NN47205-301 02.01 20 October 2008 Copyright © 2007-2008 Nortel Networks...
  • Page 60: Nortel Ethernet Routing Switch 4500 Series

    While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice.

Table of Contents