2 .1 .2 System configuration and connection examples

The system configuration and connection examples are as follows.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
HINT
• The AeroDR SYSTEM, AeroDR SYSTEM 2 and SKR 3000 can be used together.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
 Basic configuration example
Number
Name
(1)
DR Detector
(2)
AeroDR Interface Unit
(3)
AeroDR Interface Unit2
(4)
Hub
(5)
Detector Interface Unit
(6)
Detector Interface Unit 2
(7)
Power Supply Unit
AeroDR Generator Interface
(8)
Unit
AeroDR Generator Interface
(9)
Unit2
(10)
Generator Interface Unit 3
(11)
AeroDR Battery Charger
AeroDR Battery Charger2 Charges the DR Detector. It also has the registration function for the DR Detector.
(12)
(13)
AeroDR Access Point
(14)
Access Point
• There are 9 types of DR Detectors: AeroDR 1417HQ, AeroDR 1417S, AeroDR
1717HQ, AeroDR 1012HQ, AeroDR 2 1417HQ, AeroDR 2 1417S, AeroDR 3 1417HD,
AeroDR 3 1717HD and AeroDR 3 1012HQ.
• DR Detector is of B-type Applied Parts.
• Supplies power to the AeroDR Generator Interface Unit, AeroDR Generator Interface
Unit2, and access point.
• Supplies power to and charges the DR Detector when the wired cable is used.
• It has a built-in hub function.
• 2 DR Detectors can be connected via wired connection.
• The expansion AeroDR Interface Unit is required for connecting the third to seventh DR
Detectors via wired connection.
• Supplies power to the access point.
• Supplies power to and charges the DR Detector when the wired cable is used.
• It has a built-in hub function.
• 2 DR Detectors can be connected via wired connection.
• The expansion AeroDR Interface Unit is required for connecting the third to seventh DR
Detectors via wired connection.
• Relays signals between the X-ray device, the DR Detector, and the image processing con-
troller.
• Used to connect the AeroDR Generator Interface Unit2 or access point.
• General-purpose product.
• Product conforming to IEC 60950 (CLASS I) or equivalent standards.
• Relays signals between the DR Detector and the image processing controller.
• Supplies power to the DR Detector.
• Relays signals between the DR Detector and the image processing controller.
• Supplies power to the DR Detector.
• Relays signals for serial exposure.
• Supplies power to the Detector Interface Unit, Detector Interface Unit 2, AeroDR Generator
Interface Unit, AeroDR Generator Interface Unit2, Generator Interface Unit 3 and access point.
• Relays signals between the Detector Interface Unit, Detector Interface Unit 2, AeroDR
Generator Interface Unit, AeroDR Generator Interface Unit2, Generator Interface Unit 3, access
point and the image processing controller.
Relays signals between the X-ray device, the DR Detector, and the image processing con-
troller.
Relays signals between the X-ray device, the DR Detector, and the image processing con-
troller.
• Relays signals between the X-ray device, the DR Detector, and the image processing
controller.
• Relays signals for serial exposure, using GIU3 Serial I/F Kit.
Charges the DR Detector. It also has the registration function for the DR Detector.
This communicates with DR Detector when performing an exposure using wireless connec-
tion.
• This communicates with DR Detector when performing an exposure using wireless con-
nection.
• General-purpose product.
• The AeroDR Access Point 2 is included.
35