Remote Power Supply
Operation and Features
Items of note for operation:
The RPS will come with open bays and a corresponding number of Remote Power
Supply Modules (RPSM).
Clarity Matrix G3 LCD Video Wall System Installation Guide
020-1339-00H
• If an RPS is switched off or placed in low power mode, there is a 30 second wait
time until the RPS will begin its boot process. Additionally, if the same RPSM is
removed and reinstalled prior to 30 seconds passing, there is a minimum 30
second wait time prior to that RPSM being ready to output power. The breaker
switch is best for resetting power to displays.
• If there is a sudden loss of load to the RPS and then a sudden addition of load to
the RPS during operation, the RPS will reboot. If the breaker switch is used to
power down and up equipment, it is best to do this cycle one at a time.
• The RPS will not enable DC output power unless all RPSM are installed and
associated AC power is applied for any particular configuration. If the unit is AC
powered prior to installing all the RPSM, a power reset is required.
• Each breaker is fixed at 25A. Loads for more than a few seconds beyond this
point will trip the breaker.
• Only Planar branded RPSMs are rated to work in this system.
• Fans within the system are internally thermally controlled. The system has been
designed to nominally run at 40dB or less at 25°C (77°F), 0m (0kft). Acoustic
noise beyond this point is dictated by the power draw and environmental
conditions.

Remote Power Supply Operation and Features

Page | 164