3. Wiring the Power Inputs

The rear panel of the L3 Managed Switch has an AC power socket, one DC power
on/off switch and one DC inlet terminal block within 2 screws.
10G/1G
 DC Inlet Terminal Block
The DC inlet terminal block accepts DC power input voltage from 36V to 60V DC.
Connect the power cable to the L3 Managed Switch at the DC input terminal block;
the size of the two screws in the terminal block is M3.5.
Please follow the steps below to insert the DC power wire.
1. Insert the negative wire (Black) into the "V-" connector and tighten the wire-
clamp to prevent the DC wire from loosening.
2. Insert the positive wire (Red) into the "V+" connector and tighten the wire-
clamp to prevent the DC wire from loosening.
3. Power on the L3 Managed Switch by switching it to the "ON" position.
Figure 3-2: L3 Managed Switch DC Inlet Terminal Block
Before connecting the DC power cable to the input terminal block
of the L3 Managed Switch, make sure that the power switch is in
the "OFF" position and the DC power is OFF.
Warnin g
The wire gauge for the terminal block should be in the range from
12 to 24 AWG.
Note
10G
ACT
1G
ACT
49
50
51
52
10G/1G
10G/1G
10G/1G
Figure 3-1: L3 Managed Switch Rear Panel
CAUTION
Ensure the power switch
in the "OFF" position
V+
before connect the DC wire.
DC Input Range
36-60V
CAUTION
Ensure the power switch
in the "OFF" position
V+
before connect the DC wire.
DC Input Range
36-60V
DC POWER
ON
OFF
, 2A max.
DC POWER
100-240V
, 1.2A max.
ON
50/60Hz
OFF
, 2A max.
5

Advertisement

Table of Contents
loading

Table of Contents