Safe Torque Off (Sto) Safety Function; Function Description - Siemens SINAMICS G120D Operating Instructions Manual

Distributed converter, control units with encoder evaluation
Hide thumbs Also See for SINAMICS G120D:
Table of Contents

Advertisement

6.8

Safe Torque Off (STO) safety function

These operating instructions describe the commissioning of the STO safety function when it
is controlled via a fail-safe digital input.
You can find a detailed description of all safety functions and their control using PROFIsafe
in the "Safety Integrated" function manual.
6.8.1

Function description

What does the STO safety function do?
An inverter with active STO function prevents energy supply to the motor. The motor can no
longer generate torque at the motor shaft.
Consequently, the STO function prevents the starting of an electrically-driven machine
component.
Table 6- 37
1. The inverter recognizes the selection of STO
2. The inverter interrupts the energy supply to the
3. The inverter signals that "STO is active" via a
Image 6-44
If the motor is still rotating (B) when STO is selected, then it coasts down to standstill.
Converter with control units CU240D-2
Operating Instructions, 07/2016, FW V4.7 SP6, A5E34262100B AD
Overview of the manuals (Page 347)
The principle of operation of STO
Safe Torque Off (STO)
via a safety-relevant input or via the PROFIsafe
safe communication.
motor.
safety-relevant output or via the PROFIsafe
safe communication.
Functionality of STO when the motor is at standstill (A) and rotating (B)
Advanced commissioning
6.8 Safe Torque Off (STO) safety function
Standard inverter functions linked with STO
---
If you use a motor holding brake, the inverter
closes the brake.
---
217

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu240d-2

Table of Contents