Mr. Heater MH80KTR Operating Instructions And Owner's Manual page 4

Kerosene forced-air heater
Table of Contents

Advertisement

Available languages

Available languages

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
3.­ Slide­the­large­washer,­then­wheel­onto­the­axle­next­to­the­
cotter­pin.
4.­ Slide­the­spacer­onto­the­axle­next­to­the­wheel.
5.­ Slide­the­partially­assembled­axle­through­the­wheel­support­
frame.
6.­ Slide­the­spacer­onto­the­axle­next­to­the­wheel­support.
7.­
Slide­the­wheel,­then­large­washer­onto­the­axle­and­hold­in­
place­with­the­remaining­cotter­pin.
8.­ Install­the­caps­over­the­larger­washers­to­finish­the­wheel­
assembly.
PREPARING FOR OPERATION
1.­ Check­the­heater­for­possible­shipping­damage.­If­any­is­
found,­immediately­contact­the­manufacturer­at­
800-251-0001.
2.­ Follow­all­of­the­"Precautions".­
3.­ Fill­the­fuel­tank­with­clean­kerosene.­In­extremely­cold­
weather,­condensation­may­develop­in­the­tank­and­it­is­
recommended­that­a­tablespoon­of­de-icer­be­added­for­
each­gallon­(3.78­Liters)­of­fuel­in­the­tank.­When­filling­the­
heater,­use­at­least­2­gallons­(7.57­liters)­of­fuel.­Be­sure­
heater­is­level­and­do­not­overfill.­Use­a­funnel­or­can­with­a­
long­fill­spout.
IMPORTANT: Before filling fuel tank the first time or after ex-
tended storage periods, drain the fuel tank of any moisture
or condensation.
4.­ Locate­heater­at­a­safe­distance­from­combustible­materials.­
Models­MH50KR­&­MH80KTR­are­not­suitable­for­use­on­
wood­floors­or­other­combustible­materials.­When­used,­the­
heater­should­rest­on­suitable­insulating­material­at­least­1­
inch­thick­and­extending­3­ft.­or­more­beyond­the­heater­in­
all­directions.
HEATER START UP
1.­ MH50KR:­Plug­the­heater­into­a­grounded­115V,­60­Hz,­1­
Ø­outlet.
MH80KTR, MH140KTR, MH185KTR & MH210KTR: Turn­
thermostat­to­lowest­setting,­and­make­sure­"On/Off"­
switch­is­"Off".­Plug­the­heater­into­a­grounded­115V,­60­
Hz,­1­Ø­outlet.­Turn­thermostat­to­highest­setting.­Start­
heater­by­pushing­toggle­switch­to­"On"­position­(light­
signifies­switch­is­in­"ON"­position).­Adjust­thermostat­to­
desired­setting.­Heater­will­cycle­on/off­as­heat­is­required.
EXTENSION­CORD­REQUIREMENTS:­Up­to­100'­(30.5m)­use­
16­awg.­conductor.­101'­-­200'­(30.5­-­61.0m)­use­14­awg.­
conductor.
For all models:
•­ In­cold­weather­(below­10°­F),­starting­may­be­improved­by­
holding­a­finger­over­the­vent­hole­of­the­pump­adjustment­
screw­cap­until­the­heater­starts.­
•­ This­unit­is­equipped­with­an­interrupt­circuit.­The­reset­is­
integrated­into­the­"On/Off"­switch.­If­the­unit­does­not­
start,­toggle­the­switch­to­"Off",­wait­5­min.­and­toggle­
the­switch­to­"On".
HEATER SHUT DOWN
1.­ MH50KR: Unplug­heater­from­power­source.
MH80KTR, MH140KTR, MH185KTR & MH210KTR: Push­
"On/Off"­switch­to­"Off"­position.­For­extended­shutdown,­
unplug­heater­from­power­source.
Mr. Heater, Inc. | Kerosene Forced Air Heater
RESTART AFTER SAFETY SHUTDOWN­(MH50KR, MH80KTR,
MH140KTR, MH185KTR & MH210KTR) See page 7
MH50KR­-­Unplug­unit.­Wait­5­minutes.­Plug­back­in.
MH80KTR,­MH140KTR,­MH185KTR­&­MH210KTR­-­Toggle­switch­
to­"OFF"­position,­wait­5­minutes.­Restart.
MAINTENANCE AND STORAGE
WARNING.­To­prevent­personal­injury,­unplug­the­heater­from­
the­wall­outlet­before­servicing.­
For­maximum­efficiency­and­trouble-free­service,­make­the­
following­periodic­maintenance,­cleaning­and­inspections.
ADJUSTING PUMP PRESSURE
Due­to­varying­fuel­viscosities­and­normal­component­wear­the­
pump­pressure­on­this­heater­may­need­to­be­adjusted.­­
IMPROPER­PRESSURE­ADJUSTMENT
FUEL­PRESSURE­ADJUSTMENT­SCREW
­­­­­­­­­­­­­­­­­­­­­­­­­­(located­at­the­rear­of­the­heater)
ADJUSTMENT­PROCEDURE
1.­Fill­fuel­tank.
2.­Start­heater.
3.­Locate­the­pressure­adjustment­screw­and­pressure­tap,­
pictured­above,­located­on­the­back­of­the­power­pack­
assembly­and­accessible­by­the­handle­of­the­heater.
4.­Remove­and­the­rubber­cap­over­the­fuel­pressure­adjustment­
screw.
5.­Using­a­flat­bladed­screw­driver,­turn­the­pump­pressure­
adjustment­screw:
•­clockwise­
­to­increase­pump­pressure
•­counter-clockwise­
By­using­the­installed­pressure­gauge­you­may­quantitatively­
calibrate­the­pressure.­The­manufacturer's­recommended­pump­
pressures­are­in­the­specifications­chart­on­page­3.
6.­The­desired­qualitative­burner­characteristics­are­that­the­nose­
cone­in­the­combustion­chamber­should­be­cherry­red­with­no­
dark­spots­and­the­flame­should­not­extend­beyond­the­nose­
cone.
Problem: ­­ Heater­does­not­have­a­strong­consistent­flame.
­
­
Heater­smokes­and­spits­raw­fuel.
­
­
Nose­cone­does­not­get­cherry­red.
Adjustment:­Pump­pressure­is­too­low.­­
­
­
Turn­adjustment­screw­clockwise­to­increase­pump­­
­
­
pressure.
4
Operating Instructions and Owner's Manual
PRESSURE­GAUGE
­to­decrease­pump­pressure­­

Hide quick links: