Test Run Narrative; Run 1; Test Conditions Summary; Appliance Operation And Test Settings - United States Stove Company KP5522-P Manual

Pellet-fired room heater
Table of Contents

Advertisement

Test Run Narrative

Run 1

Run 1 was performed on 2/18/2022 as an attempted integrated test run per EPA ALT-
146/ ASTM E2779. The overall test duration was 360 minutes. The particulate emissions
rate for the integrated test run was 1.5 g/hr. The run had an overall HHV efficiency of
76%. Sample train A was changed at 1 hr. All test results were appropriate and valid
and the burn rate requirements for the integrated test run were achieved. There were no
anomalies and all criteria were met.

Test Conditions Summary

Testing conditions for all runs fell within allowable specifications of ASTM E2779 and
ASTM E2515. A summary of facility conditions, fuel burned, and run times is listed below.
Ambient (°F)
Runs
Pre
Post
1
69
69

Appliance Operation and Test Settings

The appliance was operated according to procedures as described in the Operations
Manual, found in Appendix B submitted with this report. Detailed run information can be
found in Appendix A submitted with this report.
Settings & Run Notes
Run 1
Heat Setting #5
Page | 8
Average
Relative
Barometric
Humidity (%)
Pressure
(In. Hg.)
Pre
Post
26.2
23.4
30.47
Pre-Burn
High Segment: Heat Setting #5
Medium Segment: Heat Setting #3
Low Segment: Heat Setting #1
Project # 22-753
Preburn
Test Fuel
Test Fuel
Fuel
Weight
Moisture
Weight
(lbs)
(lbs)
5.4
19.2
Test Run
Model: KP5522
Test Run
Time
(%DB)
(Min)
4.37
360