Results; Summary Table - United States Stove Company KP5522-P Manual

Pellet-fired room heater
Table of Contents

Advertisement

Results

The integrated test run emission rate for test Run 1 was measured to be 1.5 g/hr with a
Higher Heating Values efficiency of 76% and a CO emission rate of 0.15 g/min. The
calculated first hour particulate emission rate was 2.8 g/hr. The United States Stove
Company Model KP5522 Pellet-Fired Room Heater meets the 2020 PM emission
standard of ≤ 2.0 g/hr per CFR 40 part 60, §60.532 (b).
Detailed individual run data can be found in Appendix A submitted with this report.

Summary Table

Segments
Run
Date
Number
Setting
H
M
1
2/18/2022
L
OA
Page | 7
EPA Application Table
Run
Heat
Time
Output
Emissions
(min)
(BTU/hr)
BR
2.26
60
32591
1.58
120
22312
0.97
180
13640
1.39
360
19708
Project # 22-753
1st Hr
CO
Integrated
Emissions
Total (g/hr)
(g/hr)
(g/min)
0.21
0.17
2.8
1.5
0.12
0.15
Model: KP5522
Overall
Overall
Heating
CO
Heating
Efficiency
Emissions
Efficiency
(%HHV)
(g/min)
(%HHV)
77%
76%
0.15
76%
76%
76%

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents