United States Stove
Company
Project # 23-114
Model: SP1000E
Additional Models: KP1000E, AP1000E,
US1000E
Type: Pellet-Fired Room Heater
June 14, 2023
ASTM E2779 Standard Test Method for
Determining Particulate Matter
Emissions from Pellet Heaters (EPA
ALT-146)
Contact: Mr. John Voorhees
227 Industrial Park Road
South Pittsburg, TN 37380
John.voorhees@usstove.com
423-837-2100
Prepared by: Sebastian Button,
Laboratory Supervisor
11785 SE Highway 212 – Suite 305
Clackamas, OR 97015-9050
(503) 650-0088
WWW.PFSTECO.COM

Advertisement

Table of Contents
loading

Summary of Contents for United States Stove Company SP1000E

  • Page 1 United States Stove Company Project # 23-114 Model: SP1000E Additional Models: KP1000E, AP1000E, US1000E Type: Pellet-Fired Room Heater June 14, 2023 ASTM E2779 Standard Test Method for Determining Particulate Matter Emissions from Pellet Heaters (EPA ALT-146) Contact: Mr. John Voorhees...
  • Page 2 Project # 23-114 Model: SP1000E Revision History 6/14/2023 – Original Issue Page | 2...
  • Page 3: Table Of Contents

    Project # 23-114 Model: SP1000E Contents Affidavit ................................. 4 Introduction ..............................5 Notes ................................. 5 Pellet Heater Identification and Testing ......................6 Test Procedures and Equipment ........................7 Results ................................8 Summary Table ............................8 Test Run Narrative ............................ 8 Run 1 ..............................
  • Page 4: Affidavit

    Project # 23-114 Model: SP1000E Affidavit PFS-TECO was contracted by United States Stove Company (US Stove) to provide testing services for the SP1000E Pellet-Fired Room Heater per ASTM E2779, Determining PM Emissions from Pellet Heaters. All testing and associated procedures were conducted at PFS-TECO’s Portland Laboratory on 5/19/2023.
  • Page 5: Introduction

    Model: SP1000E Introduction US Stove of South Pittsburg, TN contracted with PFS-TECO to perform EPA certification testing on SP1000E Pellet-Fired Room Heater. All testing was performed at PFS-TECO’s Portland Laboratory. Testing was performed by Mr. Sebastian Button. Notes • Prior to start of testing, 50 hours of conditioning was performed by the manufacturer at a medium heat setting, per ASTM E2779 •...
  • Page 6: Pellet Heater Identification And Testing

    Project # 23-114 Model: SP1000E Pellet Heater Identification and Testing • Appliance Tested: SP1000E • Serial Number: N/A – Prototype Unit; PFS Tracking #0149 • Manufacturer: US Stove • Catalyst: No • Heat exchange blower: Integral • Type: Pellet Stove •...
  • Page 7: Test Procedures And Equipment

    Project # 23-114 Model: SP1000E Test Procedures and Equipment All Sampling and analytical procedures were performed by Sebastian Button. procedures used are directly from ASTM E2779 and ASTM E2515. See the list below for equipment used. See Appendix C submitted with this report for calibration data.
  • Page 8: Results

    3.2 g/hr. The US Stove Model SP1000E Pellet-Fired Room Heater meets the 2020 PM emission standard of ≤ 2.0 g/hr per CFR 40 part 60, §60.532 (b). Detailed individual run data can be found in Appendix A submitted with this report.
  • Page 9: Test Conditions Summary

    Project # 23-114 Model: SP1000E Test Conditions Summary Testing conditions for all runs fell within allowable specifications of ASTM E2779 and ASTM E2515. A summary of facility conditions, fuel burned, and run times is listed below. Average Preburn Relative Test Fuel...
  • Page 10: Appliance Description

    Model(s): SP1000E Appliance Type: Pellet-Fired Room Heater Additional Models: Certification testing was performed on the model SP1000E. This model series is branded under a several different names, including the KP1000E, AP1000E , and the US1000E. Models under these various brand names utilize the same basic design with respect to performance and emissions controls.
  • Page 11 Project # 23-114 Model: SP1000E Appliance Front Appliance Left Page | 11...
  • Page 12 Project # 23-114 Model: SP1000E Appliance Right Appliance Rear Page | 12...
  • Page 13: Test Fuel Properties

    Project # 23-114 Model: SP1000E Test Fuel Properties Test fuel used was Energex Wood Pellet Fuel, a PFI Certified Premium Pellet Brand. A sample of pellets was sent to Twin Ports Testing for analysis, see report below. Page | 13...
  • Page 14: Pellet Fuel Analysis

    Project # 23-114 Model: SP1000E Pellet Fuel Analysis Page | 14...
  • Page 15: Sampling Locations And Descriptions

    Project # 23-114 Model: SP1000E Sampling Locations and Descriptions Sample ports are located 16.5 feet downstream from any disturbances and 2 feet upstream from any disturbances. Flow rate traverse data was collected 8 feet downstream from any disturbances and 4 feet upstream from any disturbances. (See below).
  • Page 16: Sampling Methods

    Project # 23-114 Model: SP1000E Sampling Methods ASTM E2515 was used in collecting particulate samples. The dilution tunnel is 12 inches in diameter. All sampling conditions per ASTM E2515 were followed. No alternate procedures were used. Analytical Methods Description All sample recovery and analysis procedures followed ASTM E2515 procedures. At the...
  • Page 17: Sealed Unit

    Project # 23-114 Model: SP1000E Sealed Unit Page | 17...
  • Page 18: List Of Appendices

    Project # 23-114 Model: SP1000E List of Appendices The following appendices have been submitted electronically in conjunction with this report: Appendix A – Test Run Data, Technician Notes, and Sample Analysis Appendix B – Labels and Manuals Appendix C –Equipment Calibration Records Appendix D –...
  • Page 19 SP1000E 50 Hour Conditioning Medium Burn Rate Minutes Scale Weight Ambient Exhaust 2/21/2023 8:55 63.9 206.07 2/21/2023 9:25 130.4 66.48 274.47 2/21/2023 9:55 129.1 69.03 277.15 2/21/2023 10:25 127.7 71.06 273.7 2/21/2023 10:55 126.2 70.94 283.96 2/21/2023 11:25 124.8 72.77 281.48...
  • Page 20 2/22/2023 6:25 1290 67.1 71.73 280.95 2/22/2023 6:55 1320 65.5 72.14 279.01 2/22/2023 7:25 1350 71.74 280.38 2/22/2023 7:55 1380 62.4 74.65 277.13 2/22/2023 8:25 1410 60.9 76.37 282.22 2/22/2023 8:55 1440 59.4 77.4 285.32 2/22/2023 9:25 1470 57.8 79.32 283.39 2/22/2023 9:55 1500...
  • Page 21 2/23/2023 4:00 1080 77.13 280.25 2/23/2023 4:30 1110 31.5 76.88 278.87 2/23/2023 5:00 1140 77.15 280.96 2/23/2023 5:30 1170 28.5 77.11 277.33 2/23/2023 6:00 1200 77.21 282.52 2/23/2023 6:30 1230 25.5 76.7 277.05 2/23/2023 7:00 1260 24.1 76.49 277.09 2/23/2023 7:30 1290 22.6 76.99...
  • Page 22 The link ed image cannot be display ed. The file may hav e been mov ed, renamed, or deleted. Verify that the link points to the correct file and location. BRANDON BARRY VP OF ENGINEERING O  1 423 837 2100 ext 4513    E  brandon@usstove.com UNITED STATES STOVE COMPANY 227 Industrial Park Road · South Pittsburg  Tennessee · 37380 · USA · usstove.com...
  • Page 23 PELLET TEST DATA PACKET ASTM E2779/E2515 Run 1 Data Summary Client: USSC Model: SP1000 Job #: 23-114 Tracking #: Test Date: 5/19/2023 5/24/2023 Techician Signature Date PFS-TECO...
  • Page 24 Run Data.xlsm TEST RESULTS - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: Run #: Technician: Date: 5/19/2023 Burn Rate Summary High Burn Rate (dry kg/hr) 2.75 Medium Burn Rate (dry kg/hr) 1.05 Medium Burn Rate Target: <...
  • Page 25 Run Data.xlsm Overall Pellet Test Efficiency Results Manufacturer: USSC Model: SP1000 Date: 05/19/23 Run: 1 Control #: 23-114 Test Duration: 360 Output Category: Integrated Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis Overall Efficiency 75.0% 82.9% Combustion Efficiency 99.5% 99.5% Heat Transfer Efficiency...
  • Page 26 Run Data.xlsm Max Burn Rate Segment Efficiency Results Manufacturer: USSC Model: SP1000 Date: 05/19/23 Run: 1 Control #: 23-114 Test Duration: 60 Output Category: Maximum Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis Overall Efficiency 76.4% 84.4% Combustion Efficiency 99.5% 99.5%...
  • Page 27 Run Data.xlsm Medium Burn Rate Segment Efficiency Results Manufacturer: USSC Model: SP1000 Date: 05/19/23 Run: 1 Control #: 23-114 Test Duration: 120 Output Category: Medium Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis Overall Efficiency 75.0% 82.9% Combustion Efficiency 99.5% 99.5%...
  • Page 28 Run Data.xlsm Minimum Burn Rate Segment Efficiency Results Manufacturer: USSC Model: SP1000 Date: 05/19/23 Run: 1 Control #: 23-114 Test Duration: 180 Output Category: Minimum Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis Overall Efficiency 71.3% 78.8% Combustion Efficiency 99.5% 99.5%...
  • Page 29 Run Data.xlsm DILUTION TUNNEL & MISC. DATA - ASTM E2779 / E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: Run #: Technician: Test Start Time: 9:28 Date: 5/19/2023 High Burn End Time (min): Medium Burn End Time (min): Pre-Test Post Test Avg.
  • Page 30 Run Data.xlsm PELLET STOVE PREBURN DATA - ASTM E2779 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: Technician: Date: 5/19/2023 Recording Interval (min): Run Time (min): Average: -0.070 Flue Draft (in Elapsed Time Scale Weight Change Flue (°F) Ambient (°F) (min)
  • Page 31 Run Data.xlsm PELLET STOVE PREBURN DATA - ASTM E2779 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: Technician: Date: 5/19/2023 32.3 -0.04 -0.073 32.2 -0.15 -0.072 32.1 -0.09 -0.073 32.0 -0.07 -0.075 31.8 -0.24 -0.073 31.8 -0.071 31.8 -0.02...
  • Page 32 Run Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: 1 Technician: SJB Date: 5/19/2023 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter...
  • Page 33 Run Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: 1 Technician: SJB Date: 5/19/2023 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter...
  • Page 34 Run Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: 1 Technician: SJB Date: 5/19/2023 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter...
  • Page 35 Run Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: 1 Technician: SJB Date: 5/19/2023 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter...
  • Page 36 Run Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: 1 Technician: SJB Date: 5/19/2023 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter...
  • Page 37 Run Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: 1 Technician: SJB Date: 5/19/2023 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter...
  • Page 38 Run Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: 1 Technician: SJB Date: 5/19/2023 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter...
  • Page 39 Run Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: 1 Technician: SJB Date: 5/19/2023 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter...
  • Page 40 Run Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: 1 Technician: SJB Date: 5/19/2023 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter...
  • Page 41 Run Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: 1 Technician: SJB Date: 5/19/2023 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter...
  • Page 42 Run Data.xlsm BOX A TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: 1 Technician: SJB Date: 5/19/2023 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter...
  • Page 43 Run Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: Run #: Technician: Date: 5/19/2023 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 44 Run Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: Run #: Technician: Date: 5/19/2023 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 45 Run Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: Run #: Technician: Date: 5/19/2023 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 46 Run Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: Run #: Technician: Date: 5/19/2023 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 47 Run Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: Run #: Technician: Date: 5/19/2023 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 48 Run Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: Run #: Technician: Date: 5/19/2023 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 49 Run Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: Run #: Technician: Date: 5/19/2023 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 50 Run Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: Run #: Technician: Date: 5/19/2023 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 51 Run Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: Run #: Technician: Date: 5/19/2023 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 52 Run Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: Run #: Technician: Date: 5/19/2023 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 53 Run Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: Run #: Technician: Date: 5/19/2023 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 54 Run Data.xlsm BOX B TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: Run #: Technician: Date: 5/19/2023 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 55 Run Data.xlsm BOX C TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: Technician: SJB Date: 5/19/2023 Particulate Sampling Data Gas Meter Orifice dH Elapsed Time Sample Meter Meter Vacuum Pro.
  • Page 56 Run Data.xlsm BOX C TEST DATA - ASTM E2779 / ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: Technician: SJB Date: 5/19/2023 Particulate Sampling Data Gas Meter Orifice dH Elapsed Time Sample Meter Meter Vacuum Pro.
  • Page 57 Run Data.xlsm LAB SAMPLE DATA - ASTM E2515 Client: USSC Job #: 23-114 Model: SP1000 Tracking #: 149 Run #: Technician: SJB Date: 5/19/2023 Sample ID Tare, mg Final, mg Catch, mg 244.0 Filters G542 242.0 245.2 G543 242.9 244.0 C - 1st Hour G544 243.5...
  • Page 58 ASTM E2779 Wood Heater Run Sheets Client: USSC Job Number: F23-114 Tracking #: 149 Model: SP1000 Run Number: 1 Test Date: 5/19/2023 Pellet Heater Control Settings High Burn Rate Settings: Heat Level 5 – Damper Open Medium Burn Rate Settings: Heat Level 2 – Damper Closed Low Burn Rate Settings: Heat Level 1 –...
  • Page 59 REVISION HISTORY Version Number Issue Date Summary of Changes Version 1.0 20-Sep-22 Initial release into the BMS DOCUMENT APPROVAL Version Number Approval Date Approved by Version 1.0 20-Sep-22 John Steinert...
  • Page 63 Twin Ports Testing, Inc. 1301 North 3rd Street Superior, WI 54880 715-392-7114 800-373-2562 715-392-7163 www.twinportstesting.com Report No: USR:W223-0247-01 Issue No: Analytical Test Report PFS-TECO Client: Signed: 11785 SE Hwy 212 Ste 305 Clackamas, OR 97015 Sebastian Button Attention: Amber Anderson Chemist PO No: 5/11/2023...
  • Page 64 Run Data.xlsm Equations and Sample Calculations – ASTM E2779 & E2515 Client USSC Model: SP1000 Tracking #: Run: Equations used to calculate the parameters listed below are described in this appendix. Sample calculations are provided for each equation. The raw data and printout results from a sample run are also provided for comparison to the sample calculations.
  • Page 65 Run Data.xlsm – Weight of test fuel burned during test run, dry basis, kg ASTM E2779 equation (1) = (M )(100/(100 + FM)) Where, average fuel moisture of test fuel, % dry basis weight of test fuel in hopper at start of test run, wet basis, kg weight of test fuel in hopper at end of test run, wet basis, kg Sample Calculation: FM = 6.36 %...
  • Page 66 Run Data.xlsm – Weight of test fuel burned during test run segment i , dry basis, kg BSidb ASTM E2779 equation (2) = (MS )(100/(100 + FM)) BSidb Siwb ESiwb Where, weight of test fuel in hopper at start of test run segment i , wet basis, kg SSiwb weight of test fuel in hopper at end of test run segment i , wet basis, kg ESiwb...
  • Page 67 Run Data.xlsm BR – Average dry burn rate over full integrated test run, kg/hr ASTM E2779 equation (3) 60 M θ Where, θ = Total length of full integrated test run, min Sample Calculation: = 6.34 θ = 360 60 x 6.34 1.06 kg/hr Page 4 of 18...
  • Page 68 Run Data.xlsm – Average dry burn rate over test run segment i , kg/hr ASTM E2779 equation (4) 60 M BSidb θ Where, Total length of test run segment i , min θ Sample Calculation (from medium burn rate segment): 2.11 BSidb θ...
  • Page 69 Run Data.xlsm – Average gas velocity in the dilution tunnel, ft/sec ASTM E2515 equations (9)       Where: Adjustment factor for center of tunnel pitot tube strav , ASTM E2515 Equation (1) placement, Fp = scent Dilution tunnel velocity calculated after the multi-point pitot traverse at the center, ft/sec scent Dilution tunnel velocity calculated after the multi-point pitot traverse, ft/sec...
  • Page 70 Run Data.xlsm – Average gas flow rate in dilution tunnel, dscf/hr ASTM E2515 equation (3) Where: 3600 Conversion from seconds to hours (ASTM method uses 60 to convert in minutes) Water vapor in gas stream, proportion by volume; assume 2% Cross sectional area of dilution tunnel, ft Standard absolute temperature, 528 °R Absolute average gas static pressure in dilution tunnel, = P...
  • Page 71 Run Data.xlsm – Volume of Gas Sampled Corrected to Dry Standard Conditions, dscf m(std) ASTM E2515 equation (6)           Where: 17.64 °R/in. Hg Volume of gas sample measured at the dry gas meter, dcf Dry gas meter calibration factor, dimensionless Barometric pressure at the testing site, in.
  • Page 72 Run Data.xlsm – Total Particulate Matter Collected, mg ASTM E2515 Equation (12) Where: mass of particulate matter from probe, mg mass of particulate matter from filters, mg mass of particulate matter from filter seals, mg Sample Calculation: Using equation for Train A: Using equation for Train B: Page 9 of 18 PFS-TECO...
  • Page 73 Run Data.xlsm - Concentration of particulate matter in tunnel gas, dry basis, corrected to standard conditions, g/dscf ASTM E2515 equation (13) Where: Constant, 0.001 g/mg Total mass of particulate matter collected in the sampling train, mg Volume of gas sampled corrected to dry standard conditions, dscf m(std) Sample calculation: For Train A:...
  • Page 74 Run Data.xlsm – Total Particulate Emissions, g ASTM E2515 equation (15) −   Where: Concentration of particulate matter in tunnel gas, g/dscf Concentration particulate matter room air, g/dscf Average dilution tunnel gas flow rate, dscf/hr θ Total time of test run, minutes Sample calculation: For Train A = ( 0.000049 -...
  • Page 75 Run Data.xlsm PR - Proportional Rate Variation ASTM E2515 equation (16) Where: θ = Total sampling time, min θ = Length of recording interval, min = Volume of gas sample measured by the dry gas meter during the “ith” time interval, dcf = Volume of gas sample as measured by dry gas meter, dcf = Average gas velocity in the dilution tunnel during the "ith"...
  • Page 76 Run Data.xlsm – Average particulate emissions for full integrated test run, g/hr ASTM E2779 equation (5) = 60 (E /θ) Where, = Total particulate emissions, grams θ = Total length of full integrated test run, min Sample Calculation: (Dual train average) = 6.09 g θ...
  • Page 77 Run Data.xlsm – Average particulate emission factor for full integrated test run, g/dry kg of fuel burned ASTM E2779 equation (6) Where, = Total particulate emissions, grams = Weight of test fuel burned during test run, dry basis, kg Sample Calculation: (Dual train average) = 6.09 g 6.34 kg...
  • Page 78 Run Data.xlsm Stack Loss Efficiency and CO emissions calculations are done in accordance with CSA B415.1, using the password protected excel spreadsheet provided with the test standard. No alterations or alternative calculations are used for determining efficiency or CO emissions. The following pages are a sample of the calculations page from the B415.1 Spreadsheet (V2_4 - Dated April 15, 2010).
  • Page 79 Manufacturer: USSC Model: SP1000 Air Fuel Ratio (A/F) Date: 05/19/23 Overall Heating Efficiency: 75.05% Dry Molecular Weight (M 29.31 Note: In the “Input data”, "Calc. % O Run: Combustion Efficiency: 99.50% Dry Moles Exhaust Gas (N 1010.74 ", "Fuel Properties", and “Mass Balance”...
  • Page 80 Moisture Content M 5.98 Combustion Efficiency: 99.50% Moisture of Wood (wet basis): 5.98 Dry kg : 6.34 Initial Dry Weight Wt (kg): Total Input (kJ): 124,598 118,175 (Btu) 6.34 Total Output (kJ): 93,509 88,688 (Btu) Moisture Content Dry 6.36 Efficiency: 75.05% 44.87 Total CO (g):...
  • Page 81 SUMS AVERAGE SUMS 68.6 -21.1 3262.71 3010.12 296.00 47334.29 155293.27 43864.62 721085.77 -89980.02 746347.83 59927.20 4664.47 29983.75 -482.62 30466.4 94482.6 -392.9 Energy Losses (kJ/kg of Dry Fuel) Change - Ambient to Stack Temperature Room Total Flue Gas Constituent Temp Flue Gas Constituent Loss Total Chemical...
  • Page 82 According to the information provided, you seek an alternative test method for use when conducting testing on the United States Stove Company, Model KP5517 pellet heater. Currently, as required by section 60.534(a)(l)(i) of Subpart AAA, a manufacturer has the option to test their appliance in accordance with 40 CFR part 60, Appendix B, Method 28R for a crib fuel appliance or ASTM E2779-10 “Standard Test Method for Determining Particulate Matter Emissions from...
  • Page 83 the position(s) as needed to achieve a burn rate that is ≤ 50% of the maximum burn rate.” Table 1 of ASTM E2779-10 also notes that the Medium Burn Rate Category test must be ≤ 50% of the maximum burn rate. The memorandum states that this is incorrect as it assumes that zero is the other bound for determining half of the maximum burn rate, and that the correct approach in determining the Medium Burn Rate Category should be at a level below 50% of the span between the Maximum Burn Rate and the Low Burn Rate (a non-zero value).
  • Page 84 Group Leader Measurement Technology Group Angelina Brashear – EPA/OAQPS/AQAD Chuck French – EPA/OAQPS/SPPD Rafael Sanchez – EPA/OECA Robert Scinta – EPA/OECA Michael Toney – EPA/OAQPS/AQAD Nathan Topham – EPA/OAQPS/SPPD John Voorhees – United States Stove Company Chet Wayland – EPA/OAQPS/AQAD...
  • Page 85 02/02/2022 MEMORANDUM SUBJECT: Appropriate calculation of Medium Burn Rate Category in ASTM E-2779 Testing FROM: Steffan Johnson Digitally signed by STEFFAN Group Leader STEFFAN JOHNSON Date: 2022.02.02 Measurement Technology Group JOHNSON 08:28:07 -05'00' Air Quality Assessment Division Robert Scinta, P.E. Chief, Air Branch Monitoring, Assistance, and Media Programs Division Office of Compliance, Office of Enforcement and Compliance Assurance...
  • Page 86 The correct application of this requirement would be to determine the Medium Burn Rate Category at a level below 50% of the span between the Maximum Burn Rate and the Low Burn Rate (a non-zero value). Ergo, the correct calculation for finding that midpoint of 50% is defined For example, if the Maximum Burn rate of an appliance is 1.79 kg/hr and the minimum is 1.23 kg/hr, the method would currently place the 50% requirement at 0.895 kg/hr.
  • Page 87 Owner’s Instruction and Operation Manual Model Number: SP1000E Certified to ASTM E1509-2022, and CAN/ULC S627:2023 Mobile Home / Transportable Building Approved * All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary. 854042-2103M Save These Instructions In A Safe Place For Future Reference.
  • Page 88 INTRODUCTION This manual describes the installation and operation of the Breckwell, SP1000E wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s emission limits for wood heaters sold after May 15, 2020. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 6,580 to 39,121 Btu/hr, 1.0 g/hr, and 75% efficiency.
  • Page 89 INSTALLATION CHECKLIST Your wood stove should be installed by a qualified installer only. An NFI qualified Installer can be found at www.nficertified. org/public/find-an-nfi-pro/ For customer service, please contact your Breckwell dealer. COMMISSIONING CHECKLIST This checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference. Failure to install and commission according to the manufacturer’s instructions and complete this checklist will invalidate the warranty.
  • Page 90 INSTALLATION CAUTION: SAFETY NOTICE • DO NOT UNPLUG THE STOVE IF YOU SUSPECT A • IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE MALFUNCTION. TURN THE ON/OFF SWITCH TO FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, ”OFF’ AND CONTACT YOUR DEALER. FOLLOW THE INSTALLATION INSTRUCTIONS.
  • Page 91 INSTALLATION authority having jurisdiction. DO NOT USE MAKESHIFT only: 2” (51 mm) inside diameter pipe may be used for the MATERIALS OR COMPROMISES IN THE INSTALLATION first 5 feet of combustion air supply run. From 5 to 10 feet, OF THIS UNIT. INSTALL VENT AT CLEARANCES SPECIFIED use 2-3/4”...
  • Page 92 INSTALLATION VENTING a. Not less than 3 feet above any forced air inlet located within 10 feet; This unit is certified for use with listed TYPE PL-Vent, 3” or 4” (diameter in size. The stove was tested with Simpson b. Not less than 4 feet below or horizontally from, or 1 Duravent brand.
  • Page 93 INSTALLATION 3. Install a blanking plate and the chimney pipe, and if 12” MINIMUM used the outside air pipe, as shown. CLEARANCE TO ROOF VERTICAL 4. Attach the L-Vent adapter, a section of pipe and clean- ROOF VENT out tee, making sure the clean-out tee is centered in the chimney flue area.
  • Page 94 INSTALLATION hardening mastic. Slip the storm collar over the pipe, pipe. The illustration is only an example. Please and while holding the pipe at the proper elevation, conform to any local building codes or regulations affix the collar with a minimum of 3-1/4” (83 mm) having jurisdiction before you have a qualified installer stainless steel sheet metal screws.
  • Page 95 INSTALLATION DO NOT connect the unit to a GFCI socket. Voltage or star washer to penetrate paint or protection coating to variations can lead to serious performance problems. ensure grounding. This unit must be securely fastened to the The Breckwell electrical system is designed for 120V AC floor of the mobile home/transportable building through the with no more than 5% variation.
  • Page 96 OPERATION NEVER OPERATE THIS PRODUCT WHILE UNATTENDED PANEL CONTROLS CAUTION: DO NOT USE THIS CONTROL DURING NORMAL OPERATION BECAUSE IT COULD SMOTHER THE FIRE AND LEAD TO A DANGEROUS SITUATION. HIGH FAN SWITCH • The room air fan speed varies directly with the feed rate. The “High Fan”...
  • Page 97 OPERATION prevent the stove from tripping the high temp thermodisc. If MANUAL MODE the high temp thermodisc does trip, see “Safety Features.” • USE THIS MODE EXCLUSIVELY IF YOU DO NOT CONNECT AN OPTIONAL THERMOSTAT. CAUTION: • In this mode, the stove will operate only from the control panel as detailed in the “Operation”...
  • Page 98 OPERATION 1. Garbage; than pellets is not permitted. It will violate the building codes for which the stove has been approved and will void 2. Lawn clippings or yard waste; all warranties. The design incorporates automatic feed of 3. Materials containing rubber, including tires; the pellet fuel into the fire at a carefully prescribed rate.
  • Page 99 OPERATION NOTE: During the first few fires, your stove will emit an odor CAUTION: as the high-temperature paint cures or becomes seasoned to • DO NOT OPERATE YOUR STOVE WITH THE VIEWING the metal. Maintaining smaller fires will minimize this. Avoid DOOR OPEN.
  • Page 100 OPERATION TAMPER WARNING two or three days to remove accumulated ash on the tubes, which reduces the efficiency of your unit. Insert the handle This wood heater has a manufacturer-set minimum low burn end (with hole) of the cleaning tool onto the cleaning rod. rate that must not be altered.
  • Page 101 OPERATION CAUTION: CAUTION: • DO NOT OPERATE YOUR STOVE IF YOU SMELL SMOKE IF THE STOVE IS INSTALLED IN A ROOM WITHOUT COMING FROM IT. TURN IT OFF, MONITOR IT, AND AIR CONDITIONING, OR IN AN AREA WHERE DIRECT CALL YOUR DEALER. SUNLIGHT CAN SHINE ON THE UNIT, IT IS POSSIBLE THIS CAN CAUSE THE TEMPERATURE OF THE STOVE TO •...
  • Page 102 MAINTENANCE Remove the ashes periodically to avoid unnecessary ash pellets that are sticking to the hopper surface. Clean as build up. Remove ashes when unit has cooled. Ashes needed. should be placed in a metal container with a tight fitting lid.
  • Page 103 MAINTENANCE “ON” button with the viewing door open). Vacuum out the Monthly or Daily Weekly hopper. Thoroughly clean the burn pot, and firebox. It may as needed be desirable to spray the inside of the cleaned hopper with Burn Pot Stirred Empty an aerosol silicone spray if your stove is in a high humidity...
  • Page 104 TROUBLESHOOTING GUIDE When your stove acts out of ordinary, the first reaction is to call for help. This guide may save time and money by enabling you to solve simple problems yourself. Problems encountered are often the result of only five factors: 1) poor fuel; 2) poor operation or maintenance;...
  • Page 105 TROUBLESHOOTING GUIDE SMOKE SMELL COMING BACK INTO THE HOME Possible Causes: Possible Remedies: Inspect all vent pipe connections. Make sure they are sealed with RTV silicone that has There is a leak in the vent pipe a temperature rating of 500°F or higher. Also, seal joints with UL-181-AP foil tape. system.
  • Page 106 TROUBLESHOOTING GUIDE STOVE SHUTS OFF AND THE #3 LIGHT FLASHES Possible Causes: Possible Remedies: (Unplug stove first when possible) The control board is not sending There should be a 5-volt (approximately) current going to the POF thermodisc after the power to the POF thermodisc or stove has been on for 10 minutes.
  • Page 107 TROUBLESHOOTING GUIDE STOVE WILL NOT FEED PELLETS, BUT FUEL FEED LIGHT COMES ON AS DESIGNED Possible Causes: Possible Remedies: Start by emptying the hopper. Then remove the auger motor by removing the auger pin. Remove the auger shaft inspection plate in the hopper so that you see the auger shaft.
  • Page 108 TROUBLESHOOTING GUIDE HIGH LIMIT SWITCH KEEPS TRIPPING Possible Causes: Possible Remedies: convection blower Clean any dust off the windings and fan blades. If oiling the blower does not help, the overheating and tripping the blower may be bad internal temperature shutoff. The stove is being left on the The highest level setting is designated for use over short periods of time.
  • Page 109 ELECTRICAL DIAGRAM MOLEX CONNECTOR BROWN MOLEX CONNECTOR DETAIL BROWN POF THERMODISC AIR SWITCH HOPPER HIGH TEMP. IGNITER SWITCH THERMODISC PURPLE AUGER MOTOR WHITE COMBUSTION CONVECTION POWER OUTLET DETAIL BLOWER BLOWER LOOKING FROM THE REAR WHITE WHITE OF THE STOVE ENSURE THE WIRES ARE CONNECTED TO THE BOTTOM TWO PRONGS OF THE HOPPER SWITCH AS SHOWN.
  • Page 110 REPLACEMENT PARTS © 2023 Breckwell...
  • Page 111 REPLACEMENT PARTS Contact an Authorized Dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety. Part # Description Part # Description 69971 Ash Pan 80641 Exhaust Blower 88174 Gasket-Flat (3/16T X 3/8W) 26793 Cabinet Back...
  • Page 112 REPLACEMENT PARTS Contact an Authorized Dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety. Part # Description Part # Description 893919 Wood Handle 40915 Cast Door - 2023 83788 Socket Head Screw 83575...
  • Page 113 ITEMS DEFINED © 2023 Breckwell...
  • Page 114 SERVICE RECORD It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. SERVICE PROVIDER Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions.
  • Page 143 LIMITED LIFETIME WARRANTY (Wood and Pellet) 851937F The operation of this unit in a manner inconsistent with the with the Owner’s Manual supplied with the heater and the owner’s manual will void the warranty and is also against issue does not fall under a situation of exclusion, Breckwell federal regulations.
  • Page 144 LIMITATIONS OF LIABILITY supply, or handling devices such as exhaust fans or forced air furnaces or other such causes; (6) use of fuels other than The owner’s exclusive remedy and Breckwell’s sole obligation those specified in the operating instructions; (7) installation under this warranty, under any other warranty, express or or use of components not supplied with appliance or any implied, or in contract, tort or otherwise, shall be limited...
  • Page 147 State of California to cause cancer, birth defects, and/or other reproductive harm. For emissions standards. more information, go to www.P65warnings.ca.gov THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2023 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 148 State of California to cause emissions standards. cancer, birth defects, and/or other reproductive harm. For more information, go to www.P65warnings.ca.gov THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2023 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 149 State of California to cause emissions standards. cancer, birth defects, and/or other reproductive harm. For more information, go to www.P65warnings.ca.gov THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2023 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 150 / ou d’autres troubles de la reproduction. Pour plus d’informations, de particules 2020. visitez www.P65warnings.ca.gov CE MANUEL EST SUJET À MODIFICATION SANS PRÉAVIS. © 2023 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 151 / ou d’autres troubles de la reproduction. de particules 2020. Pour plus d’informations, visitez www.P65warnings.ca.gov CE MANUEL EST SUJET À MODIFICATION SANS PRÉAVIS. © 2023 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 152 / ou d’autres troubles de la reproduction. Pour plus d’informations, de particules 2020. visitez www.P65warnings.ca.gov CE MANUEL EST SUJET À MODIFICATION SANS PRÉAVIS. © 2023 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 153 Corner / Coin Non-Combustible Floor Protection / Un Protecteur de sol Clearances to Combustibles: Mur Arriére/Paroi Latérale Non-Combustible MODEL / MODÈLE : SP1000E Residential and Mobile Home / 2 in (50mm) both sides of exhaust Dégagements Combustibles: Dans Une Résidence ou Une...
  • Page 154 Dry Gas Meter Calibration Manufacturer: APEX Model: XC-60 Lab ID #: Serial #: 1902130 Calibration Date: 1/26/2023 Calibration Expiration: 7/26/2023 Barometric Pressure: 30.51 in. Hg Ref. Std. DGM Equipment Used: Thermometer Barometer Manometer Manufacturer: Apex Fluke Aquatech Dwyer Model: SK25DA 52 II DBX2 Lab ID#: 47...
  • Page 155 Dry Gas Meter Calibration Manufacturer: APEX Model: XC-60 Lab ID #: Serial #: 1902133 Calibration Date: 1/26/2023 Calibration Expiration: 7/26/2023 Barometric Pressure: 30.49 in. Hg Ref. Std. DGM Equipment Used: Thermometer Barometer Manometer Manufacturer: Apex Fluke Aquatech Dwyer Model: SK25DA 52 II DBX2 Lab ID#: 47...
  • Page 156 Dry Gas Meter Calibration Manufacturer: APEX Model: XC-50-DIR Lab ID #: Serial #: A2204292 Calibration Date: 1/26/2023 Calibration Expiration: 7/26/2023 Barometric Pressure: 30.50 in. Hg Ref. Std. DGM Equipment Used: Thermometer Barometer Manometer Manufacturer: Apex Fluke Aquatech Dwyer Model: SK25DA 52 II DBX2 Lab ID#: 47...
  • Page 157 Dry Gas Meter Calibration Manufacturer: APEX Model: Apex-AK-600 Lab ID #: Serial #: 810016 Calibration Date: 1/27/2023 Calibration Expiration: 7/27/2023 Barometric Pressure: 30.15 in. Hg Ref. Std. DGM Equipment Used: Thermometer Barometer Manometer Manufacturer: Apex Fluke Aquatech Dwyer Model: SK25DA 52 II DBX2 Lab ID#: 47...
  • Page 158 Report and Certificate of Calibration Report #: 28140-203326-14 Customer PO#: 1090 Customer Name: PFS TECO Customer Address: 11785 SE Highway 212 Ste 305 City: Clackamas State: OR Zip: 97015 Contact: Aaron Kravitz Service Address: 11785 SE Highway 212 Ste 305 Clackamas, OR 97015 Calibration Standards 19-00269 | Thermo-Hygrometer | Comark | SN: 6237360167 | Cal: 09/14/2022 | Due: 08/31/2023 | Vendor: Cal-Cert | Range: 122 °F 95 %RH | Report #: 25699-30694-3486...
  • Page 159 Newport Pressure Transducer Unknown Manufacturer: Type: Serial #: Remarks: We sincerely thank you for your business. Please call us at 503-654-9620 for all your sales and calibration needs. Cleaning and preventative maintenance were performed as part of this service. Cal-Cert is accredited by A2LA under Calibration Laboratory Code #4986.01. A2LA is recognized under the ILAC mutual recognition agreement (MRA).
  • Page 160 Report and Certificate of Calibration Report #: 28140-203325-14 Customer PO#: 1090 Customer Name: PFS TECO Customer Address: 11785 SE Highway 212 Ste 305 City: Clackamas State: OR Zip: 97015 Contact: Aaron Kravitz Service Address: 11785 SE Highway 212 Ste 305 Clackamas, OR 97015 Calibration Standards 19-00269 | Thermo-Hygrometer | Comark | SN: 6237360167 | Cal: 09/14/2022 | Due: 08/31/2023 | Vendor: Cal-Cert | Range: 122 °F 95 %RH | Report #: 25699-30694-3486...
  • Page 161 Newport Pressure Transducer Unknown Manufacturer: Type: Serial #: Remarks: We sincerely thank you for your business. Please call us at 503-654-9620 for all your sales and calibration needs. Cleaning and preventative maintenance were performed as part of this service. Cal-Cert is accredited by A2LA under Calibration Laboratory Code #4986.01. A2LA is recognized under the ILAC mutual recognition agreement (MRA).
  • Page 162 Report and Certificate of Calibration Report #: 28140-203324-14 Customer PO#: 1090 Customer Name: PFS TECO Customer Address: 11785 SE Highway 212 Ste 305 City: Clackamas State: OR Zip: 97015 Contact: Aaron Kravitz Service Address: 11785 SE Highway 212 Ste 305 Clackamas, OR 97015 Calibration Standards 19-00269 | Thermo-Hygrometer | Comark | SN: 6237360167 | Cal: 09/14/2022 | Due: 08/31/2023 | Vendor: Cal-Cert | Range: 122 °F 95 %RH | Report #: 25699-30694-3486...
  • Page 163 Newport Pressure Transducer Unknown Manufacturer: Type: Serial #: Remarks: We sincerely thank you for your business. Please call us at 503-654-9620 for all your sales and calibration needs. Cleaning and preventative maintenance were performed as part of this service. Cal-Cert is accredited by A2LA under Calibration Laboratory Code #4986.01. A2LA is recognized under the ILAC mutual recognition agreement (MRA).
  • Page 164 Report and Certificate of Calibration Report #: 28140-203324-14 Customer PO#: 1090 Customer Name: PFS TECO Customer Address: 11785 SE Highway 212 Ste 305 City: Clackamas State: OR Zip: 97015 Contact: Aaron Kravitz Service Address: 11785 SE Highway 212 Ste 305 Clackamas, OR 97015 Calibration Standards 19-00269 | Thermo-Hygrometer | Comark | SN: 6237360167 | Cal: 09/14/2022 | Due: 08/31/2023 | Vendor: Cal-Cert | Range: 122 °F 95 %RH | Report #: 25699-30694-3486...
  • Page 165 Newport Pressure Transducer Unknown Manufacturer: Type: Serial #: Remarks: We sincerely thank you for your business. Please call us at 503-654-9620 for all your sales and calibration needs. Cleaning and preventative maintenance were performed as part of this service. Cal-Cert is accredited by A2LA under Calibration Laboratory Code #4986.01. A2LA is recognized under the ILAC mutual recognition agreement (MRA).
  • Page 166 Report and Certificate of Calibration Report #: 28134-206391-14 Customer PO#: 1090 Customer Name: PFS TECO Customer Address: 11785 SE Highway 212 Ste 305 City: Clackamas State: OR Zip: 97015 Contact: Aaron Kravitz Service Address: 11785 SE Highway 212 Ste 305 Clackamas, OR 97015 Calibration Standards 19-00269 | Thermo-Hygrometer | Comark | SN: 6237360167 | Cal: 09/14/2022 | Due: 08/31/2023 | Vendor: Cal-Cert | Range: 122 °F 95 %RH | Report #: 25699-30694-3486...
  • Page 167 Manufacturer: National Instruments Type: Data Logger Serial #: 1B182FB Type K Thermocouple METER FUNCTION Calibration UUT As Left UUT As Left As Left Expanded Channel Standard As Found Reading 1 Reading 2 Error Uncertainty± 0.10 0.10 0.10 0.10 Filter A 0.00 500.10 500.10...
  • Page 168 Manufacturer: National Instruments Type: Data Logger Serial #: 1B182FB Type K Thermocouple METER FUNCTION Calibration UUT As Left UUT As Left As Left Expanded Channel Standard As Found Reading 1 Reading 2 Error Uncertainty± -0.50 -0.50 -0.50 -0.50 Left 0.00 499.70 499.70 499.70...
  • Page 169 Manufacturer: National Instruments Type: Data Logger Serial #: 1B182FB Type K Thermocouple METER FUNCTION Calibration UUT As Left UUT As Left As Left Expanded Channel Standard As Found Reading 1 Reading 2 Error Uncertainty± -1.00 -1.00 -1.00 -1.00 Bottom 0.00 499.20 499.20 499.20...
  • Page 170 Manufacturer: National Instruments Type: Data Logger Serial #: 1B182FB Type T Thermocouple METER FUNCTION Calibration UUT As Left UUT As Left As Left Expanded Channel Standard As Found Reading 1 Reading 2 Error Uncertainty± 0.00 0.00 0.00 0.00 Ambient 0.00 17.70 17.70 17.70...
  • Page 171 Report and Certificate of Calibration Report #: 28134-206391-14 Customer PO#: 1090 Customer Name: PFS TECO Customer Address: 11785 SE Highway 212 Ste 305 City: Clackamas State: OR Zip: 97015 Contact: Aaron Kravitz Service Address: 11785 SE Highway 212 Ste 305 Clackamas, OR 97015 Calibration Standards 19-00269 | Thermo-Hygrometer | Comark | SN: 6237360167 | Cal: 09/14/2022 | Due: 08/31/2023 | Vendor: Cal-Cert | Range: 122 °F 95 %RH | Report #: 25699-30694-3486...
  • Page 172 Manufacturer: National Instruments Type: Data Logger Serial #: 1B182FB Type K Thermocouple METER FUNCTION Calibration UUT As Left UUT As Left As Left Expanded Channel Standard As Found Reading 1 Reading 2 Error Uncertainty± -0.60 -0.60 -0.60 -0.60 Filter A 0.00 499.50 499.50...
  • Page 173 Manufacturer: National Instruments Type: Data Logger Serial #: 1B182FB Type K Thermocouple METER FUNCTION Calibration UUT As Left UUT As Left As Left Expanded Channel Standard As Found Reading 1 Reading 2 Error Uncertainty± -1.30 -1.30 -1.30 -1.30 Left 0.00 498.90 498.90 498.90...
  • Page 174 Manufacturer: National Instruments Type: Data Logger Serial #: 1B182FB Type K Thermocouple METER FUNCTION Calibration UUT As Left UUT As Left As Left Expanded Channel Standard As Found Reading 1 Reading 2 Error Uncertainty± -1.50 -1.50 -1.50 -1.50 Bottom 0.00 498.80 498.80 498.80...
  • Page 175 Manufacturer: National Instruments Type: Data Logger Serial #: 1B182FB Type T Thermocouple METER FUNCTION Calibration UUT As Left UUT As Left As Left Expanded Channel Standard As Found Reading 1 Reading 2 Error Uncertainty± -1.40 -1.40 -1.40 Ambient 0.00 -1.40 18.80 18.80 18.80...
  • Page 176 Report and Certificate of Calibration Report #: 28140-203320-14 Customer PO#: 1090 Customer Name: PFS TECO Customer Address: 11785 SE Highway 212 Ste 305 City: Clackamas State: OR Zip: 97015 Contact: Aaron Kravitz Service Address: 11785 SE Highway 212 Ste 305 Clackamas, OR 97015 Calibration Standards 19-00269 | Thermo-Hygrometer | Comark | SN: 6237360167 | Cal: 09/14/2022 | Due: 08/31/2023 | Vendor: Cal-Cert | Range: 122 °F 95 %RH | Report #: 25699-30694-3486...
  • Page 177 Red Lion Pressure Transducer Unknown Manufacturer: Type: Serial #: Remarks: We sincerely thank you for your business. Please call us at 503-654-9620 for all your sales and calibration needs. Cleaning and preventative maintenance were performed as part of this service. Cal-Cert is accredited by A2LA under Calibration Laboratory Code #4986.01.
  • Page 178 Report and Certificate of Calibration Report #: 28140-203319-14 Customer PO#: 1090 Customer Name: PFS TECO Customer Address: 11785 SE Highway 212 Ste 305 City: Clackamas State: OR Zip: 97015 Contact: Aaron Kravitz Service Address: 11785 SE Highway 212 Ste 305 Clackamas, OR 97015 Calibration Standards 19-00269 | Thermo-Hygrometer | Comark | SN: 6237360167 | Cal: 09/14/2022 | Due: 08/31/2023 | Vendor: Cal-Cert | Range: 122 °F 95 %RH | Report #: 25699-30694-3486...
  • Page 179 Red Lion Pressure Transducer Unknown Manufacturer: Type: Serial #: Remarks: We sincerely thank you for your business. Please call us at 503-654-9620 for all your sales and calibration needs. Cleaning and preventative maintenance were performed as part of this service. Cal-Cert is accredited by A2LA under Calibration Laboratory Code #4986.01.
  • Page 180 JJ Calibrations, Inc. Certificate of Calibration 7724 SE Aspen Summit Drive Portland, OR 97266-9217 743892 Certificate Number: Phone 503.786.3005 FAX 503.786.2994 PFS TECO 11785 SE Hwy 212 1033 Suite 305 03/08/2021 Order Date: Clackamas, OR 97015 0723.01 Authorized By: Calibration Property #: Calibrated on: 03/18/2021...

This manual is also suitable for:

Kp1000eAp1000e

Table of Contents