Sampling Methods; Analytical Methods Description; Calibration, Quality Control And Assurances; Appliance Sealing And Storage - United States Stove Company KP5522-P Manual

Pellet-fired room heater
Table of Contents

Advertisement

Project # 22-753
Model: KP5522

Sampling Methods

ASTM E2515 was used in collecting particulate samples. The dilution tunnel is 12 inches
in diameter. All sampling conditions per ASTM E2515 were followed. No alternate
procedures were used.

Analytical Methods Description

All sample recovery and analysis procedures followed ASTM E2515 procedures. At the
end of each test run, filters, O-Rings and probes were removed from their housings,
dessicated for a minimum of 24 hours, and then weighed at 6 hour intervals to a
constant weight per ASTM E2515-11 Section 10.

Calibration, Quality Control and Assurances

Calibration procedures and results were conducted per EPA Method 28R, ASTM E2515-
11 and ASTM E2780-10. Test method quality control procedures (leak checks, volume
meter checks, stratification checks, proportionality results) followed the procedures
outlined.

Appliance Sealing and Storage

Upon completion of testing, the appliance was secured with metal strapping and the seal
below was applied, the appliance was then returned to the manufacturer's location at:
227 Industrial Park Road, South Pittsburg, TN 37380 for archival.

Sealing Label

Page | 15