D7212GV2 | Operation and Installation Guide | 9.0

Figure 12: Program Record Sheet

D9412GV2/D7412GV2 | Program Record Sheet | RADXPNTS Handler
Default values are shown in ( ) or in bold
Point Assignments (001 through 040)
POPIT Switch
Setting
0 1 2 3 4 5 6
9.3.8

POPIT Labels

D7212GV2 off-board points are numbered 9 to 40.
Two sheets of peel-off POPIT labels are supplied with
the D8125 POPEX Module. Use the sheet marked
"Bank1" for Points 9 to 40.
Each label has two parts. Place the smaller part, with
only the point number, on the chip. Place the larger
part, with the switch settings, on the base of the POPIT.
Set the switches and cover the POPIT.
Do not program two POPITs for the same point
number. After programming all the points, perform a
Service Walk Test. The D9412GV2/D7412GV2/
D7212GV2 Installation and Troubleshooting Quick Reference
Guide (P/N: F01U003638) contains instructions for
performing a Service Walk Test. If a point does not
test, check the programming for a duplicated address.
Walk Test and Service Walk Test Do Not Show
Extra Points: If the point assignment switches on a
POPIT or OctoPOPIT are set incorrectly, missing and
extra point conditions might occur. If the same point
number is assigned to two or more POPITs or
OctoPOPITs, none of the points with that number test
correctly. Refer to Section 9.1 Point (Zonex) Bus:
D7212GV2 Terminals on page 6.
36
Trans-
Point
Point
Area
lation
#
Index
Assign
100
001
(3)
_ _
(1)
200
002
(1)
_ _
(1)
300
003
(25) _ _
(1)
400
004
(13) _ _
(1)
500
005
(7)
_ _
(1)
600
006
(7)
_ _
(1)
700
007
(7)
_ _
(1)
800
008
(7)
_ _
(1)
101
009
__ __
(1)
Off-Board Points
bold
BFSK/
Debounce
Relay
___
(2)
_____
(1)
____
___
(2)
_____
(2)
____ P2 PANIC
___
(2)
_____
(3)
____ P3 DELAY
___
(2)
_____
(4)
____ P4 FOLLOW ___________________
___
(2)
_____
(5)
____ P5 INSTANT ___________________
___
(2)
_____
(6)
____ P6 INSTANT ___________________
___
(2)
_____
(7)
____ P7 INSTANT ___________________
___
(2)
_____
(8)
____ P8 INSTANT ___________________
___
(2)
_____
(1)
____ P9
9.4

D8128D OctoPOPIT Module

Use only the D8128D OctoPOPIT Module.
Using Modules D8128, D8128A, or D8128B
can cause intermittent MISSING and
RESTORAL reports.
9.4.1

Description

The D8128D OctoPOPIT Module combines the
functions of the D8125 POPEX Module and the
D8127/D9127 POPIT Modules to provide eight off-
board points in a single module. You can wire both
D8128D OctoPOPIT and D8125 POPEX Modules in
parallel to the Zonex bus terminals on the same control
panel.
Review Section 6.0 Power Outputs on page 24 to ensure
there is enough power for the OctoPOPITs and other
powered devices that will be connected to the system.
Up to four D8128Ds can be connected to the
D7212GV2 Control Panel (three points can be used on
the last OctoPOPIT).
9.4.2

Listings

The D8128D OctoPOPIT Module is UL Listed for
Local or Police Connected Burglary Alarm, Central
Station Burglary Alarm, Household Burglary Alarm
applications, and commercial fire applications (UL 864
and NFPA 72).
The D8128D is also suitable for fire supervisory
applications, such as indicating circuit supervision
(using the D192C/D192G Bell Circuit Supervision
Module), sprinkler supervision, and valve tamper
protection. Do not connect fire-alarm initiating device
directly to D8128D.
Bosch Security Systems, Inc. | 5/05 | F01U003805B
EN | 25
Custom Point Text
___________________
P1 FIRE
___________________