6 Commissioning
6.2.2

Selection of command source

Selection of command source
P0700 =...
Selects digital command source.
0
Factory fault setting
1
BOP (keypad)
2
Terminal
5
USS
6.2.3

Digital inputs (DIN)

Function of digital input 0
P0701=...
Terminal 3
Function digital input 1
P0702 =...
Terminal 4
Function digital input 2
P0703 =...
Terminal 5
Function digital input 3
P0704 =...
Via analog input (AIN version only)
Terminals 9, 10
FF selection (15, 16) not possible
Debounce time for digital inputs
P0724 =...
Defines debounce time (filtering time) used
for digital inputs.
0
No debounce time
1
2.5 ms debounce time
2
8.2 ms debounce time
3
12.3 ms debounce time
2-wire/3wire control method
P0727 =...
Determines the control method using the terminals
0 Siemens Standard (Start / Direction)
1 2-wire (FWD / REV)
2 3-wire (FWD P / REV P)
3 3-wire (Start P / Direction)
"P" denotes "Pulse"; "FWD" denotes "FORWARD"; "REV" denotes "REVERSE"
Redefined Digital Inputs
Settings P0701 – P0704
DIN channel
18
2 / 5
1
12
9
0
3
P0727=0
Siemens standard control
1
ON/OFF1
2
ON REV/OFF1
12
REV
Kl.6 P24
Debounce time for digital inputs
Kl.7 0 V
24 V
0 V
P0700
G110 AIN
G110 USS
0
X
1
X
2
X
5
Possible Settings:
0
Digital input disabled
1
ON / OFF1
2
ON Reverse / OFF1
3
OFF2 – coast to standstill
4
OFF3 – quick ramp-down
9
Fault acknowledge
10
JOG right
11
JOG left
12
Reverse
13
MOP up (increase frequency)
14
MOP down (decrease frequency)
15
Fixed setpoint (Direct selection)
16
Fixed setpoint (Direct selection + ON)
21
Local/remote
25
DC brake enable
29
External trip
See P0727 for redefinition of settings 1, 2, 12
P0727=1
P0727=2
2-wire control
3-wire control
ON_FWD
STOP
ON_REV
FWDP
REV
REVP
Function of digital input 0
0 ... 29
0 ... 3
P0701 (1)
P0724 (3)
T
0
&
r0722
r0722
CO/BO: Binary input values
Operating Instructions (Compact)
Issue 11/04
Settings
X
X
X
See 6.2.3
X
See 6.2.1
0
P0727=3
3-wire control
ON_PULSE
OFF1/HOLD
REV
0
29