Command:
\Qn
Flow Control Selection
Values:
n = 0, 1, or 3
Default:
3
Description:
\Q0
\Q1
\Q2
\Q3
Command:
\Tn
Inactivity Timer
Values:
n = 0, 1–255
Default:
0
Description:
\Tn
Note:
Command:
\Vn
Protocol Result Code
Values:
n = 0, 1, or 2
Default:
1
Description:
\V0
\V1
\V2
Command:
-Cn
Data Calling Tone
Values:
n = 0 or 1
Defaults:
0
Description:
-C0
-C1
Command:
%A
Adaptive Answer Result Code Enable
Values:
n = 0 or 1
Default:
0
Description:
The %A command controls whether the DATA and FAX result codes will be sent by the
modem. The modem must be in fax mode for this command to work. Also, the modem must
be set to +FAA=1, which enables the modem to distinguish between a fax and a data call.
When these commands are enabled, the modem sends DATA to the computer when it
detects data tones, and FAX when it detects fax tones. These strings are used by some
servers to select the appropriate communication program.
%A0
%A1
Note: For descriptions of the +FAA= and other fax commands, see the Multi-Tech Fax Class
2.1 Developer's Guide.
Command:
%B
View Numbers in Blacklist
Values:
n/a
Description:
If blacklisting is in effect, AT%B displays the numbers for which the last call attempted in the
previous two hours failed. In countries that do not require blacklisting, the ERROR result
code appears.
Command:
%Cn
Data Compression Control
Values:
n = 0 or 1
Default:
1
Description:
%C0
%C1
Command:
%DCn AT Command Control
Values:
n = 0 or 1
Default:
0
Description:
%DC0
%DC1
Note: The modem will respond to AT%DC for 10 seconds after it is turned on.
Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272H)
Disables flow control (same as &K0).
XON/XOFF software flow control (same as &K4).
CTS-only flow control. Not supported.
RTS/CTS hardware flow control (same as &K3).
Sets the time (in minutes) that the modem waits after the last character is sent or
received before it disconnects. A value of zero disables the timer. Applies only in
buffer mode.
You can also set the inactivity timer by changing the value of S30.
Disables the appending of the protocol result code to the DCE speed.
Enables the appending of the protocol result code to the DCE speed.
Same as \V1.
Disables V.25 data calling tone to deny remote data/fax/voice discrimination.
Enables V.25 data calling tone to allow remote data/fax/voice discrimination.
Disables adaptive answer result codes.
Enables adaptive answer result codes.
Disable sV.42bis/MNP 5 data compression.
Enables V.42bis/MNP 5 data compression.
The modem responds to AT commands.
The modem ignores AT commands.
Chapter 1 – AT Commands