Setting Up Your Multifrad - Multitech MultiFrad FR111A User Manual

100 series one port frame relay access device with 56k dsu
Table of Contents

Advertisement

Setting Up Your MultiFRAD

If V.35 electrical interface signaling is required on the data port but a PC with EIA-232D signaling is
being used to configure the MultiFRAD, the unit has to be configured before you change to V.35
signaling. You need to set the DIP-switches, make the proper cable connections, configure the unit,
and then change to V.35 signaling on the data port.
1. Ensure that the DIP switch settings on the side of the unit are set for a command mode of
operation (i.e., Switch 1 is DOWN, Switches 2, 3 and 4 are UP).
Switch
1
2
3
4
5
6 - 8
* Factory default setting
2. Connect the external power transformer to the MultiFRAD and plug it into a live AC outlet. The
MultiFRAD does not have a power switch. When power is applied to the unit, it takes about 10
seconds for it to power-up.
FR111A
Figure 2-2. Data/Command Switch
Mode
Position
Cmd/Data
UP*
DOWN
Clocking
UP*
DOWN
Loopback
UP*
DOWN
DSU
UP
DOWN*
Force RTS
UP
DOWN*
Not Used
Power
Power Connection
RS-232 Cable
Connection
Figure 2-3. Cable Connections
Description
Data
Command
DDS
Internal
Normal
Loopback
FRAD
DSU
Follows CTS
Forced active
Data
Trunk
Chapter 2 - Installation
RJ-48 Connection
15