BASIC NETWORK
3.
Subnet Mask: Select the subnet mask for the DHCP server. The subnet mask defines how many clients are
allowed in one network or subnet. The default subnet mask is 255.255.255.0/24. This means a maximum
of 254 IP addresses are allowed in the subnet. However, the gateway's LAN IP occupies one of them.
4.
IP Pool Starting/Ending Address: Specify the IP address pool's starting/ending addresses. When there is a
request, the DHCP server will automatically allocate an unused IP address from the IP address pool to the
requesting computer.
Note:
The number of IP addresses in this IP pool must be less than the maximum number of subnet
networks according to the set subnet mask.
5.
Lease Time: DHCP lease time to the DHCP client.
6.
Domain Name: This information is passed to the clients. This is optional.
7.
Primary DNS/Secondary DNS: Assign DNS Servers. This is optional.
8.
Primary WINS/Secondary WINS: Assign WINS Servers. This is optional.
9.
Gateway: This is the alternate Gateway IP address. Assign another gateway to your computer when the
DHCP server offers an IP address. For example, the gateway will assign an IP address to local computers
but they will access the Internet through another gateway. This is optional.
10.
Server: To activate the DHCP server, check Enable.

System Management (DeviceHQ)

Signing Up with DeviceHQ and Setting Up MTE to Communicate with DeviceHQ

1.
Register and sign up a new account at https://www.devicehq.com.
2.
Log in to
https://www.devicehq.com
a.
Select Account info (to the right of the account email address) and click Edit.
b.
Check Device API Enabled and click Update Account.
c.
Click Generate new Device API Keys.
d.
Write down and save "Device API Secret" and "Device API Auth Token", these two keys are required
during MTE device setup.
Note:

Setting Up MTE UI for DeviceHQ

MTE must be running firmware version 2.04 or above for DeviceHQ support. Download firmware from the website
and upgrade the device before proceeding.
1.
In Basic Network, on the LAN Setup Screen: Enter and Define Site Name so it shows as Description in
DeviceHQ
2.
In Basic Network, on the System Management Setup Screen: DeviceHQ access setup requires:
a.
Check the Enable option.
b.
Enter DeviceHQ account API secret and API Auth Token.
c.
Click Save.
Wait for a few minutes. If MTE has an active cellular internet connection, it automatically checks in and registers
with DeviceHQ. Log in to DeviceHQ and make sure the new MTE device shows up on your account.

Setting Up a New Firmware File on DeviceHQ

This is performed after logging in to DeviceHQ.
14
DO NOT lose these keys since there is no way to see them again.
and generate a device API key using the following steps:
https://www.multitech.com/models/92506980LF
®
MultiConnect
eCell User Guide

Advertisement

Table of Contents
loading