Power cord must be
disconnected during this test.
3. Voltage Suppressor Test
p/n 32714 —
The bidirectional transient voltage
suppressor protects the portion control.
Its normal failure mode is a direct short.
Check by removing it from the board
and using an ohm meter. It should test
open in both directions.
Power cord must be
disconnected during this test
4. Proximity Switch Test
p/n 32953 —
Check ice chute interlock proximity
switch for continuity by disconnecting
the connector and using probes. There
should be less than 1 ohm of resistance.
24 VOLT POWER TESTS
Power cord must be
connected during this test.
1. Valve Banks Test —
Check the two transformers by
checking one valve in the left bank
and one valve in the right bank of
valves. If both banks operate cor-
rectly, go to step 9.
If either of the banks does not work
correctly, go to the next step.
© 2003, IMI Cornelius Inc.
Pro ED Fast Gate Training Manual
bidirectional
transient
voltage
suppressor
.
Probe the
connector
Left
valve
bank
Right valve bank
- 9 -