REP 10.2 Exit Guide Assembly and Exit Assembly
Parts List on
PL
10.10,
PL 10.15
Removal
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
Before performing this procedure, refer to General Disassembly Precautions,
1.
Remove the DADF. Refer to (4150)
2.
Remove the scanner assembly, (4150)
3.
Open the side cover assembly,
PL 7.30 Item
4.
Remove the exit guide assembly,
Figure
Figure 1 Exit guide assembly removal
Repairs and Adjustments
REP 10.2
WARNING
WARNING
CAUTION
GP
REP 5.1
or (4250/4260/4265)
REP
5.3.
REP 14.1
or (4250/4260/4265)
REP
1.
1.
2
Remove 5 screws.
3
Remove the exit
guide assembly.
1
Release the harness
from the plastic guides.
5.
Remove the exit assembly,
1
Disconnect (4150) CN6
or (4250/4260/4265)
CN8 and route the wire
harness back inside the
machine.
10.
14.3.
Replacement
Replacement is the reverse of the removal procedure.
January 2016
4-148
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
Figure
2.
2
Remove 4 screws.
3
Remove the exit assembly.
Figure 2 Exit assembly removal