Specifications - Carrier Comfort 59SC5B Product Data

95 single-stage, 4-way multipoise, condensing gas furnace
Table of Contents

Advertisement

59SC5B: Product Data

SPECIFICATIONS

The furnace should be sized to provide 100 percent of the design heating load requirement plus any margin that occurs because of furnace model size
capacity increments. None of the furnace model sizes can be used if the heating load is 12,000 BTUH or lower. Use Air Conditioning Contractors of
America (Manual J and S); American Society of Heating, Refrigerating, and Air-Conditioning Engineers; or other approved engineering method to
calculate heating load estimates and select the furnace. Excessive oversizing of the furnace may cause the furnace and/or vent to fail prematurely,
customer discomfort and/or vent freezing.
Failure to follow these guidelines is considered faulty installation and/or misapplication of the furnace; and resulting failure, damage, or repairs may
impact warranty coverage.
Furnace Model
Heating Capacity and Efficiency
Input (BTUh)
Output (BTUh)
Certified Temperature Rise Range ºF (ºC)
Airflow Capacity and Blower Data
Rated External Static
Pressure (in. w.c.)
Airflow Delivery @ Rated
ESP (CFM)
Cooling Capacity (tons) @
CFM/ton
Direct­Drive Motor Type
Direct­Drive Motor HP
Motor Full Load Amps
RPM Range
Speed Selections
Blower Wheel Dia x Width
Air Filtration System
Filter Used for Certified Watt Data
Electrical Data
Input Voltage
Operating
Voltage Range
Maximum Input Amps
Unit Ampacity
Minimum Wire Size
Maximum Wire Length@
Minimum Wire Size
Maximum Fuse/Ckt Bkr
(Time­Delay Type
Recommended)
Transfomer Capacity (24vac output)
External Control Power
Available
Controls
Gas Connection Size
Burners (Monoport)
Gas Valve (Redundant)
Minimum Inlet Gas pressure (in. wc)
Maximum Inlet Gas pressure (in. wc)
Manufactured (Mobile) Home Kit
Ignition Device
Heating Blower Control
(Heating Off­Delay)
Cooling Blower Control
(Time Delay Relay)
Communication System
Thermostat Connections
Accessory Connections
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
026E14--10
26,000
25,000
25 ­ 55
(14 ­ 31)
Heating
0.10
Cooling
0.50
Heating
605
Cooling
895
400 CFM/ton
2
350 CFM/ton
2.50
1/3
4.4
400 ­ 1200
5
in.
11 x 7
Volts­Hertz­
Phase
Min­Max
Amps
5.1
Amps
7.3
AWG
14
Feet
50
(M)
(15.5)
Amps
15
Heating
Cooling
2
Manufacturer
040E14--10
040E17--12
40,000
40,000
39,000
39,000
40 ­ 70
40 ­ 70
(22 ­ 39)
(22 ­ 39)
0.10
0.10
0.50
0.50
695
650
950
1010
2
2.5
2.50
3
Electronically Commutated Motor (ECM)
1/2
1/2
6.3
6.8
600 ­ 2000
400 ­ 1200
5
5
11 x 7
11 x 8
Field Supplied Filter
325531­40*
115­60­1
104­127
7.0
7.5
9.7
10.3
14
14
38
36
(11.7)
(10.9)
15
15
40 VA
27.9 VA
34.6 VA
1/2" ­ NPT
2
2
White Rodgers
4.50
13.60
See Accessory Listing
Silicon Nitride
Adjustable: 90, 120, 150, 180 seconds
90 seconds
none
Com 24V, R, W, G, Y
EAC (115vac); HUM (24vac); 1­stg AC (via Y)
4
060E14--12
060E17--14
60,000
60,000
58,000
58,000
45 ­ 75
40 ­ 70
(25 ­ 42)
(22 ­ 39)
0.12
0.12
0.50
0.50
930
1010
1120
1330
2.5
3.5
3
4
1/2
3/4
6.3
8.8
600 ­ 2000
400 ­ 1200
5
5
11 x 7
11 x 8
7.1
9.6
9.8
12.9
14
14
38
28
(11.5)
(8.7)
15
15
3
3

Advertisement

Table of Contents
loading