Table 6 - Technical Specifications - Carrier obm154 Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Table 6 - Technical Specifications
154 Series,
m ulti-position
models
I
UNITS WITH 1,0 HP 4-SP, MOTOR
_
UNITS WITH 1,0 HP ECM MOTOR
m
m
Firing rate (USGPH)*
0,90
1,10
0,90
1,10
Input (BTU/h)*
126 000
154 000
126 000
154 000
Maximum Heating capacity,
(BTU/h)*
107 000
129 000
107 000
129 000
Heating temperature
rise (Degr. F)*
55 - 75 Degr. F
60 - 72 Degr. F
Flue draft with chimney (inch of w .c.)
-0.06 to -0.035
-0.06 to -0.035
Overfire pressure with chimney (inch of w .c.)
-0.035 to +0.045
-0.035 to +0.045
Flue pressure
w ith direct vent (inch of w .c. - no wind)
+0.05 to +0.16
+0.05 to +0.16
Overfire pressure with direct vent (inch of w .c. - no wind)
+0.06 to +0.22
+0.06 to +0.22
_
:_MO_(_|m
_i,
_
Burner tube insertion length (inches)
Head type
Nozzle (Delavan)
Minimum and Maximum pump pressure
(PSlG)*
Head/Air setting
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
1 3/4"
6 Slots - LC head
0.75 - 60B
0.90 - 60B
145
150
3,5
4
_: 87,0%
_: 85.7%
_: 86.6%
$ 85,2%
1 3/4"
6 Slots - LC head
0.75 - 60B
0.90 - 60B
145
150
3,5
4
$ 87,0%
_: 85.7%
$ 86.6%
_: 85,2%
Burner tube insertion length (inches)
Nozzle (Delavan)
Minimum and Maximum pump pressure
(PSlG)*
Combustion air adjustment (turbulator/damper)
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
2 3/4"
0.75 - 70A
0.90 - 70A
145
150
1.5 / 2.25
2.5 / 2.75
_: 86.7%
_: 85.3%
_: 86.3%
$ 85,0%
2 3/4"
0.75 - 70A
0.90 - 70A
145
150
1.5 / 2.25
2.5 / 2.75
$ 86.7%
_: 85.3%
$ 86.3%
_: 85,0%
Burner tube insertion length (inches)
2 3/4"
2 3/4"
Nozzle (Delavan)
0.75 - 70A
0.90 - 70A
0.75 - 70A
0.90 - 70A
Minimum and Maximum pump pressure
(PSlG)*
145
150
145
150
Combustion air adjustment (turbulator/damper)
1.0 / 3.75
3.0 / 4.25
1.0 / 3.75
3.0 / 4.25
AFUE%
(From CSA B212 standard and Canadian regulation)**
_: 86.7%
_: 85.3%
$ 86.7%
_: 85.3%
AFUE%
(FromASHRAE
103 standard and US regulation)**
_: 86.3%
$ 85,0%
$ 86.3%
_: 85,0%
Volts - Hertz - Phase
115 - 60 - 1
115 - 60 - 1
Rated current (Amps)
16,9
15,7
Minimum ampacity for w ire sizing (A raps)
19,5
18,1
Max. fuse size (Amps)
20
20
Control transformer
(VA)
40
40
External control power available
Heating (VA)
40
40
Cooling (VA)
30
30
Heating blow er speed at 0.25" W.C. SP
MED-LOW
MED-HIGH
See the ECM air flow table
Heating blow er speed at 0.50" W.C. SP
MED-LOW
MED-HIGH
Motor (HP) / nun_er of speeds
1.0 HP / 4 speeds
1.0 HP / ECM (with inductor)
Blow er size (diam. x w idth)
12" x 10" (tight housing)
12" x 10" (tight housing)
....
Overall dimensions
(width x depth x height)
25" x 28 1/2" x 48"
25" x 28 1/2" x 48"
Supply air opening (width x depth)
20"x 22"
20" x 22"
Return air opening (width x depth)
23"x 23"
23" x 23"
Filter size
24" x 24" x 1"
24" x 24" x 1"
Shipping weight Lbs/Kg
200 / 90
200 / 90
Air conditioning,
maximum output (tons) at 0.5" W.C. SP
5,0
5,0
* INPUT & OUTPUT ADJUSTMENT:
- Pump pressure can be adjusted
to maintain
proper
firing
rate.
- Increase
pump pressure
if flue gases temperature
is under
400°F
- Adjust
the tota._l flue gas temperature
between
400 ° and 575°F (330 ° and 505 ° F net approx.)
- Adjust
fan speed for air temperature
rise of 55 ° to 85°F.
** AFUE value established
after minimum
20 hours of operation.
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ovm154

Table of Contents