59SP5A
Performance™ Boost, Single---Stage
4---Way Multipoise
Condensing Gas Furnace
Series 100
The 59SP5A Multipoise Performance™ Boost Condensing Gas
Furnace features SEER- -boosting year- -round electrical efficiency
when paired with a compatible condensing unit. Energy efficiency
is at the heart of this furnace with 96.5% AFUE gas efficiency and
the electrically- -efficient basic ECM blower motor. This gas furnace
also features 4- -way multipoise installation flexibility, and is
available in five model sizes. The 59SP5A can be vented for direct
vent/two- -pipe,
ventilated
applications. All units meet California Air Quality Management
District emission requirements, are design certified in Canada, and
are certified for mobile/manufactured home use.
STANDARD FEATURES
S Quiet operation. Compare for yourself at HVACpartners.com
S High- -efficiency basic ECM multiple- -speed blower motor for
electrically efficient operation all year long in heating, cooling
and continuous fan operation
S Humidistat
Control compatible; dehumidification input for
TM
better comfort
S SmartEvap™ technology helps control humidity levels in the
Product Data
combustion
air,
or
single- -pipe
TM
home when used with a compatible humidity control system
S ComfortFan™ technology allows control of continuous fan
speed from a compatible thermostat
S Ideal height 35" (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service
S Silicon Nitride Power Heat™ Hot Surface Igniter
S External Media Filter Cabinet included
S 4- -way multipoise design for upflow, downflow or horizontal
installation, with unique vent elbow and optional venting
through- -the- -cabinet downflow venting capability
S Multi- -speed ECM blower motor, single- -speed inducer motor,
and single- -stage gas valve
S Self diagnostics
S Adjustable blower speed for heating, cooling and continuous fan
S Aluminized- -steel primary heat exchanger
S Stainless- -steel condensing secondary heat exchanger
S Propane convertible (see Accessory list)
A11263
S Factory- -configured ready for upflow applications
S Fully- -insulated casing including blower section
S Convenient Electronic Air Cleaner and Humidifier connections
S Direct- -vent/sealed combustion, single- -pipe venting or
ventilated combustion air
S Installation flexibility: (sidewall or vertical vent)
S Residential installations may be eligible for consumer financing
through the Retail Credit Program

LIMITED WARRANTY*

S 10 year parts and lifetime heat exchanger limited warranty to the
original purchaser upon timely registration.
S Limited warranty period is five years for parts and twenty years
for the heat exchanger if not registered within 90 days of
installation.{
* For owner occupied, residential applications.
Jurisdictions where warranty benefits cannot be conditioned on registra-
{
tion will receive registered limited warranty benefits.
1

Advertisement

Table of Contents
loading

Summary of Contents for Carrier Performance 59SP5A

  • Page 1: Limited Warranty

    59SP5A Performance™ Boost, Single---Stage 4---Way Multipoise Condensing Gas Furnace Series 100 Product Data home when used with a compatible humidity control system S ComfortFan™ technology allows control of continuous fan speed from a compatible thermostat S Ideal height 35” (889 mm) cabinet: short enough for taller coils, but still allows enough room for service S Silicon Nitride Power Heat™...
  • Page 2: Specifications

    SPECIFICATIONS Heating Capacity and Efficiency 040-10 060-14 080-16 100-16 120-22 Input High Heat (BTUH) 40,000 60,000 80,000 100,000 120,000 Output High Heat (BTUH) 39,000 58,000 78,000 98,000 117,000 Efficiency AFUE % (ICS) 96.5 96.5 96.5 96.5 96.5 Certified Temperature 40 - 70 40 - 70 40 - 70 40 - 70...
  • Page 3: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE 1 - 2 7 - 9 11 - 12 15 - 16 Family Htg. Stages Tier Effy. Major Series Htg. Cap. Motor Width Voltage Minor Series Airflow 08 - 800 CFM Family 10 - 1000 CFM 12 - 1200 CFM S - Single Stage 14 - 1400 CFM T - Two Stage...
  • Page 4 Carrier Infinity Air Purifier - 16x25 (406x635 mm) GAPAAXCC1625-A08 Carrier Infinity Air Purifier - 20x25 (508x635 mm) GAPAAXCC2025-A08 Carrier Infinity Air Purifier Repl. Filter- 16x25 (406x635 mm) GAPACCCAR1625-A05 Carrier Infinity Air Purifier Repl. Filter- 20x25 (508x635 mm) GAPACCCAR1625-A05 EZ Flex Cabinet 16” (406 mm) EZXCABCC1016-A20 EZ Flex Cabinet 20”...
  • Page 5 AIR DELIVERY - - CFM (BOTTOM RETURN WITH FILTER) EXTERNAL STATIC PRESSURE (IN. W.C.) INPUT RETURN-AIR SPEED BTUH SUPPLY 5(Gry) 1120 1080 1030 4(Yel) 40000 SIDE/BOTTOM 3(Blu) 2(Org) 1(Red) 5(Gry) 1720 1670 1620 1565 1505 1440 1375 1295 1220 1135 4(Yel) 1325 1285...
  • Page 6 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) Table 1 – Maximum Equivalent Vent Length - - Ft. (M) 0 to 4500 Ft. (0 to 1370 M) Altitude NOTE: Maximum Equivalent Vent Length (MEVL) does NOT include elbows or terminations. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
  • Page 7 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) Table 3 – Maximum Equivalent Vent Length - - Ft. (M) 4501 to 10,000 Ft. (0 to 1370 M) Altitude NOTE: Maximum Equivalent Vent Length (MEVL) does NOT include elbows or terminations. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
  • Page 8 MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE - - FT. (M) Maximum Length of Uninsulated and Insulated Vent Pipe-Ft (M) No Insulation 3/8-in. (9.5 mm) Insulation 1/2-in. (12.7 mm) Insulation Single Winter Pipe Pipe Diameter-in. (mm) Pipe Diameter-in. (mm) Pipe Diameter-in. (mm) Stage Design Length in...
  • Page 9: Return Air Temperature

    RETURN AIR TEMPERATURE This furnace is designed for continuous return- -air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C) db such as when used with a night setback thermometer. Return- -air temperature must not exceed 80_F (27_C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls.
  • Page 10 Carrier cased coil is used. It is combustion air to be drawn in through the outer pipe.
  • Page 11: Typical Wiring Schematic

    MEDIA FILTER CABINET 25-5/8" (651mm) 24-1/4” 23-5/8" (616mm) (600mm) Opening with Flanges Bent 23-1/8” 23-3/8” (588mm) (594mm) Opening Duct Side Furnace Side 23-3/4” (603mm) " Centerline Screw Slots (146mm) A11456A DIMENSIONS (IN. / MM) MEDIA FILTER CABINET SHIPPED WITH SIZES 040--- 08, 040--- 12, 060--- 08, 16 (406.4) 17 (432.8)
  • Page 12: Dimensional Drawing

    DIMENSIONAL DRAWING A11521...
  • Page 13: Guide Specifications

    GUIDE SPECIFICATIONS General System Description Primary Heat Exchangers Furnish a ______________________ 4- -way multipoise gas- -fired Primary heat exchangers shall be 3- -Pass corrosion- -resistant condensing furnace for use with natural gas or propane (factory- - aluminized steel of fold- -and- -crimp sectional design and applied authorized conversion kit required for propane);...