Heating Capacity and Efficiency
High Heat
Input
Low Heat
High Heat
Output
Low Heat
Certified Temperature
Rise Range ºF (ºC)
Airflow Capacity and Blower Data
Rated External Static
Pressure (in. w.c.)
Airflow Delivery
@ Rated ESP (CFM)
Cooling Capacity (tons)
@ 400, 350 CFM/ton
Direct-Drive Motor Type
Direct-Drive Motor HP
Motor Full Load Amps
RPM Range
Speed Selections
Blower Wheel Dia x Width
Air Filtration System
Filter Used for Certified Watt Data
Electrical Data
Input Voltage
Operating Voltage Range
Maximum Input Amps
Unit Ampacity
Minimum Wire Size
Maximum Wire Length
@ Minimum Wire Size
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recommended)
Transformer Capacity (24vac output)
External Control Power
Available
Controls
Gas Connection Size
Burners (Monoport)
Gas Valve (Redundant)
Minimum Inlet Gas pressure (in. wc)
Maximum Inlet Gas pressure (in. wc)
Manufactured (Mobile) Home Kit
Ignition Device
Limit Control
Heating Blower Control (Heating Off-Delay)
Cooling Blower Control (Time Delay Relay)
Communication System
Thermostat Connections
Accessory Connections
* See Accessory List for part numbers available.

SPECIFICATIONS

040-10
040-12
(BTUH)
40,000
40,000
(BTUH)
26,000
26,000
(BTUH)
39,000
39,000
(BTUH)
25,000
25,000
40 - 70
40 - 70
High Heat
(22 - 39)
(22 - 39)
30 - 60
30 - 60
Low Heat
(17 - 33)
(17 - 33)
040-10
040-12
Heating
0.10
Cooling
0.5
High Heat
815
Low Heat
660
Cooling
905
400 CFM/ton
2
350 CFM/ton
2.5
1/2
6.8
in.
11 x 7
11 x 8
040-10
040-12
Volts-Hertz-Phase
Min-Max
Amps
7.5
Amps
10.3
AWG
14
Feet
36
(M)
(11.0)
(11.0)
Amps
15
Heating
Cooling
040-10
040-12
2
Manufacturer
165
060-12
060-14
080-16
60,000
60,000
80,000
39,000
39,000
52,000
58,000
58,000
78,000
38,000
38,000
50,000
40 - 70
40 - 70
40 - 70
(22 - 39)
(22 - 39)
(22 - 39)
30 - 60
30 - 60
30 - 60
(17 - 33)
(17 - 33)
(17 - 33)
060-12
060-14
080-16
0.10
0.12
0.12
0.15
0.5
0.5
0.5
0.5
860
1120
1135
1505
660
910
860
1160
1065
1065
1475
1610
2.5
2.5
3.5
3
3
4
4.5
Electronically Communicated Motor (ECM)
1/2
1/2
3/4
3/4
6.8
6.8
8.4
8.4
600 - 1200
Variable (PWM)
11 x 7
11 x 8
11 x 8
Optional Media Cabinet
Field Supplied Filter
KGAWF1506UFR
060-12
060-14
080-16
115-60-1
104-127
7.5
7.6
9.2
9.2
10.2
10.3
12.4
12.4
14
14
14
36
36
29
(11.0)
(8.8)
(8.8)
15
15
15
40 VA
24.3 VA
34.6 VA
060-12
060-14
080-16
1/2" - NPT
2
3
3
White Rodgers
4.5
13.6
not approved for MH use
Silicon Nitride
180
165
180
170
Adjustable: 90, 120, 150, 180 seconds
90 seconds
None
R, W/W1, W2 Y/Y2, Y1, G, Com 24V, DHUM
EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
4
080-20
100-20
120-22
80,000
100,000 120,000
52,000
65,000
78,000
78,000
97,000
117,000
51,000
63,000
76,000
40 - 70
40 - 70
40 - 70
(22 - 39)
(22 - 39)
(22 - 39)
30 - 60
30 - 60
30 - 60
(17 - 33)
(17 - 33)
(17 - 33)
080-20
100-20
120-22
0.15
0.20
0.20
0.5
0.5
0.5
1555
1865
2375
1200
1435
1675
2005
2005
2115
4
5
5
5
5.5
5.5
6
1
1
1
10.9
10.9
10.9
11 x 10
11 x 10 11 x 11
080-20
100-20
120-22
11.7
11.8
11.8
15.5
15.6
15.6
14
12
12
12
29
37
36
36
(11.3)
(11.0)
(11.0)
15
20
20
20
080-20
100-20
120-22
4
4
5
6
200
180
160

Advertisement