Models

Models
Full Load
Peak Amps
System
Per Phase*
24N569
90
24N570 ★✖
68
24N571
90
24N572 ★✖
68
24N573
90
24N574 ★✖
68
24N575
90
24N576 ★✖
68
Material
Ratio
System
(A:B)
24N569
24:1
24N570 ★
24N571
16:1
24N572 ★
24N573
1:1
24N574 ★
24N575
24:1
24N576 ★
27.5' (8.4 m)
Hydraulic
System
Hose Bundle
24N569
24N570 ★
24N571
24N572 ★
24V197
24N573
24N574 ★
24N575
24N576 ★
4
Primary
Heater
Voltage
Watts
(phase)
A (Red)
230V (3)
400V (3)
230V (3)
400V (3)
6,000
230V (3)
400V (3)
230V (3)
400V (3)
A (Red)
B (Blue)
Pump
Pump
A (Red)
Size
Size
Orifice
120
5
.061
160
10
.057
60
60
.039
120
5
.085
10' (3 m)
Hydraulic
Hose Bundle
24J177
Primary
Max Flow
Approximate
Heater
Rate◆
Watts
lb/min
B (Blue)
(kg/min)
18 (8.2)
0.033 (0.125)
4,000
24 (11)
0.045 (0.170)
6,000
17 (7.7)
0.032 (0.121)
4,000
18 (8.2)
0.033 (0.125)
25' (7.6 m)
B (Blue)
Chemical
Orifice
Hose Bundle
.011
24J290
.014
.039
24N287
.013
24K681
Output per
Hydraulic
Cycle (A+B)
Pressure
gal. (liter)
Ratio
1.9:1
1.4:1
3.7:1
1.9:1
10' (3 m)
Chemical
Hose Bundle
24J316
24N289
Maximum
Fluid Working
Pressure ‡
psi (MPa, bar)
2000
(14, 138)
3A2797ZAA