Pneumatic Connection - GEM 1434 mPos Operating Instructions Manual

Intelligent electro-pneumatic positioner
Table of Contents

Advertisement

13 Pneumatic connection

13.1 Standard, single acting
2
1
M5
E
No.
Designation
1
Air supply connection P
2
Working connection for process
valve A1
3
Venting connection R with integ-
rated check valve
E
Housing ventilation with integ-
rated check valve
* Only relevant for exhaust air duct and/or increase of protection
class.
Fail safe function
Error
Electrical power supply failure
Pneumatic supply failure
This fail safe function is not a substitute for specific plant
safety requirements.
Safety reaction
Error
Set value < 4.0 mA*
Set value > 20 mA or 10 V
* only for design with 4–20 mA set value input (code A)
www.gemu-group.com
3
M6 x 0,75
2
1
Connection size
M5
M5
M6 x 0.75*
M6 x 0.75*
Working connection A1
vented
undefined
Working connection A1
vented
vented
13.2 Information for use in damp conditions
The following information is intended to help when installing
and operating the product in damp conditions.
1. Cables and pipework must be laid so that condensate or
rain water that remains on the pipework/cables cannot
enter the screw fittings of the product's M12 plugs.
2. Check that all cable glands of the M12 plugs and the fit-
tings are mechanically secured.
13.3 Converting to protection class IP 67
▶ Required appropriate pneumatic connections with M5
connection thread and pneumatic lines are not included
in the kit and must be provided by the user.
The conversion kit 1434 000 Z2 comprises:
1x threaded adapter, M6x0.75 to M5
1x O-ring
The conversion kit 1434 000 Z2 is required for piped air outlet
1x and for conversion to protection class IP67 2x. For an ex-
haust air duct, only connection 3 must be used in accordance
with the following description. To increase the protection
class, connection 3 and E must be used accordingly.
1. Switch off the pneumatic control air supply.
2. Remove protective caps from the vent holes using an ap-
propriate tool.
3. Unscrew vent screws anticlockwise from the vent holes
using an Allen key WAF3 and remove.
4. Screw the threaded adapter with mounted O-ring into the
vent holes and tighten carefully.
25 / 32
13 Pneumatic connection
NOTICE
GEMÜ 1434 µPos