The Motor Of The Presenter Does Not Rotate - IBM NetVista Kiosk DBCS Hardware Service Manual

Table of Contents

Advertisement

14
Poor motor
Visually check the
connector contact
connector.
Platen open
Check the
sensor failure
continuity of the
platen sensor with
a tester.
Defective Feed
Check the
button
continuity of the
Feed button with
a tester.
Motor lead wire
Remove the
disconnection or
connector in the
defective motor
printer unit that
corresponds to
CN301 on the
board frame unit.
Next, measure the
resistance
between pins 1
and 3, and pins 2
and 4 with a
tester.
Abnormal motor
Measure the
drive circuit
motor phases and
the ground
voltage with an
oscilloscope.
4. The presenter's motor does not work.
Symptom:
The Feed button is pressed, but the motor does not run.
Possible cause
Checkpoint and
method
Upper guide is
Make sure that
open
the screw holding
the presenter to
the upper guide is
securely fastened.
Poor motor
Visually check the
connector contact
connector.
Reinsert the connector properly.
Short-circuit
Short-circuit
7.0±0.77
Replace the printer unit.
Pulse waveform
(Wave height:
approximately
24V)
Evaluation
Corrective action
criteria and
standard
Fasten the screw tightly.