Superior SDV35-2 Installation Instructions Manual page 34

Direct-vent gas fireplaces
Hide thumbs Also See for SDV35-2:
Table of Contents

Advertisement

INSTALLATION ACCESSORIES CONTINUED
Listed Secure Flex
Cat. #
These termination kits include firestop/spacer, gear clamps and flex adaptor.
60L10
98K03
H2248
H2249
56L74
56L75
f i r e - p a r t s . c o m
91L66
91L67
H7748
Cat. No.
92L09
92L10
92L11
92L06
34
SUPERIOR
• DIRECT-VENT GAS FIREPLACES (SDV35-N-2) • INSTALLATION INSTRUCTIONS
®
Components
®
Model
Description
SF-18
18 feet (5.49 m)
compressed flex
(Ref. Instr. #750053M)
SF-12
12 feet (3.66 m)
compressed flex
(Ref. Instr. #750052M)
SF4.5HF-10
Firestop / Spacer—
Horizontal, flex (3-1-1
spacing), 10 Pack
SF4.5VF-10
Firestop/Spacer—Vertical,
flex (1-1-1 spacing), 10 Pk
SFVT30
Vertical Termination for flex
(flat to 6/12) with flex adaptor,
section of rigid vent, roof
support collar assembly, roof
flashing and storm collar.
(Ref. Instr. #750052M)
SFVT45
Vertical Termination for flex
(6/12 to 12/12) with flex
adaptor, section of rigid
vent, roof support collar
assembly, roof flashing,
and storm collar.
(Ref. Instr. #750052M)
SFGC4-6
Gear Clamp 4.5 in. (114 mm)
for flex (6 pack)
SFGC7-6
Gear Clamp 7.5 in. (190.5
mm) for flex (6 pack)
H7748
36 in. Flex Connector
Kit. 36 in. of flex with
two adaptors for mating
two rigid sections of vent
together.
Thimble Components
Model
Description
SV-FSTFE
Firestop Thimble (SV) -
Flat, with Extension
SV-FST1E
Firestop Thimble
(SV) - 1/12 Pitch, with
Extension
SV-FST2E
Firestop Thimble
(SV) - 2/12 Pitch, with
Extension
SVTE26
Thimble Extension (SV) -
26 inches
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Listed Secure Flex
Cat. #
H1969
77L87
77L88
77L89
77L90
77L91
94L04*
94L05*
94L06*
94L07*
94L08*
94L09*
*
All compressed flex vents can be expanded up to two times.
Components
®
Model
Description
SF4.5HT-2
Horizontal Square Termina-
tion for flex (without flex
vent)
SFKIT12S
Square Term. for flex
(with 12 in. [305 mm]
compressed flex vent*)
SFKIT18S
Square Term. for flex
(with 18 in. [457 mm]
compressed flex vent*)
SFKIT24S
Square Term. for flex
(with 24 in. [610 mm]
compressed flex vent*)
SFKIT36S
Square Term. for flex
(with 36 in. [914 mm]
compressed flex vent*)
SFKIT48S
Square Term. for flex
(with 48 in. [1219 mm]
compressed flex vent*)
SFKIT12SS
Small Square Termination for
flex, with 12 in. (305 mm) of
compressed flex vent*
(Ref. Instr. #750204M)
SFKIT18SS
Small Square Termination for
flex, with 18 in. (457 mm) of
compressed flex vent*
(Ref. Instr. #750204M)
SFKIT24SS
Small Square Termination for
flex, with 24 in. (610 mm) of
compressed flex vent*
(Ref. Instr. #750204M)
SFKIT36SS
Small Square Termination for
flex, with 36 in. (914 mm) of
compressed flex vent*
(Ref. Instr. #750204M)
SFKIT48SS
Small Square Termination for
flex, with 48 in. (1219 mm)
of compressed flex vent*
(Ref. Instr. #750204M)
SF-HTSS
Horizontal Small Square
Termination for flex, without
flex vent
(Ref. Instr. #750204M)