8.5 Parts Replacement Procedure

8.5.1 Drum Motor

8.5.1.1 Before Removing the Drum Motor

1) Remove the ETB unit. (page 8-30)Reference[Removing the ETB Unit]
2) Remove the rear cover unit. (page 11-11)Reference[Removing the Rear
Cover Unit]
3) Remove the right cover. (page 11-11)Reference[Removing the Right
Cover]

8.5.1.2 Removing the Drum Motor

1) Disconnect the connector [1].
2) Remove the durm motor (Bk) [1].
- 3 screws [2]
[2]
MEMO:
When removing the drum motors of other colors, remove the following parts
in the same way as the drum motor (Bk).
- 3 connectors [1]
- 9 screws [2]
F-8-32
F-8-33
[2]
[2]
[2]
0020-5298
0020-5299
[1]

8.5.2 Main Drive Unit

8.5.2.1 Before Removing the Main Drive Unit

1) Remove the ETB unit. (page 8-30)Reference[Removing the ETB Unit]
2) Remove the toner cartridge.
3) Remove the rear cover unit. (page 11-11)Reference[Removing the Rear
Cover Unit]
4) Remove the right cover. (page 11-11)Reference[Removing the Right
Cover]
5) Remove the drum motor. (page 8-25)Reference[Removing the Drum
Motor]

8.5.2.2 Removing the Main Drive Unit

1) Disconnect the 4 connectors [1] and free the harness [3] from the 2 harness
guides [2].
[1]
[2]
[2]
2) Remove the duplex feed motor [1].
- 2 screws [2]
3) Free the harness [2] from the wire saddle [1].
[2]
[3]
[1]
[1]
[3]
F-8-34
[2]
[1]
[2]
F-8-35
Chapter 8
[1]
[2]
[1]
[2]
[1]
[2]
0020-5295
0020-5296
[1]
8-25