3.13 Swing raster motor

3.13.1 Checking procedures

To perform an electrical check of the swing raster motor
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01D – 2022.02
b
a Cover
b Screw
c Swing flap motor
2 Install and tighten the screw to fix the swing flap motor.
3 Connect the connector to the swing flap motor.
4 Install the cover.
Is the problem solved?
Yes
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Disconnect the swing raster motor connector from the indoor unit main PCB.
2 Measure the resistance between the following pins of the motor connector.
Result: The measurements MUST be as shown in the table below.
Pins
1-2
1-3
1-4
1-5
c
a
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
"3.10 Plate
Measured resistance (Ω)
380
3
Components
|
4
work" [
 100].
Service manual
115