Service manual
4
Table of contents
1.1
Meaning of warnings and symbols.................................................................................................................................
1.2
Dangers ...........................................................................................................................................................................
1.3
Warnings .........................................................................................................................................................................
1.4
Cautions .......................................................................................................................................................................... 13
1.5
Notices ............................................................................................................................................................................ 13
2.1
To display the error code on the user interface ............................................................................................................ 14
2.2
To reset the error code via remote controller ............................................................................................................... 14
2.3
To reset the error code via outdoor unit ....................................................................................................................... 14
2.4
To perform a test run...................................................................................................................................................... 14
2.4.1
To perform a test run in winter season ......................................................................................................... 15
2.5
Error based troubleshooting........................................................................................................................................... 15
2.5.1
A1-00 - PCB abnormality ............................................................................................................................... 15
2.5.2
A5-00 - Outdoor unit: High pressure peak cut / freeze protection problem ............................................... 16
2.5.3
A6-00 - Indoor unit fan motor abnormality .................................................................................................. 17
2.5.4
C4-00 - Heat exchanger temperature sensor problem................................................................................. 17
2.5.5
C9-00 - Room thermistor abnormality .......................................................................................................... 18
2.5.6
E1-00 - Outdoor unit: PCB defect.................................................................................................................. 18
2.5.7
E3-00 - Outdoor unit: Actuation of high pressure switch............................................................................. 19
2.5.8
E5-00 - Outdoor unit: Overheat of inverter compressor motor................................................................... 20
2.5.9
E6-00 - Outdoor unit: Compressor startup defect........................................................................................ 21
2.5.10
E7-00 - Outdoor unit: Malfunction of outdoor unit fan motor .................................................................... 22
2.5.11
E8-00 - Outdoor unit: Power input overvoltage ........................................................................................... 22
2.5.12
EA-00 - Outdoor unit: Cool/heat switchover problem ................................................................................. 23
2.5.13
F3-00 - Outdoor unit: Malfunction of discharge pipe temperature............................................................. 24
2.5.14
F6-00 - Outdoor unit: Abnormal high pressure in cooling............................................................................ 25
2.5.15
2.5.16
H0-00 - Outdoor unit: Voltage/current sensor problem .............................................................................. 26
2.5.17
H3-00 - Outdoor unit: Malfunction of high pressure switch ........................................................................ 27
2.5.18
H6-00 - Outdoor unit: Malfunction of position detection sensor ................................................................ 28
2.5.19
H8-00 - Outdoor unit: Malfunction of compressor input system................................................................. 29
2.5.20
H9-00 - Outdoor unit: Malfunction of outdoor air thermistor ..................................................................... 29
2.5.21
J3-00 - Outdoor unit: Malfunction of discharge pipe thermistor................................................................. 30
2.5.22
J6-00 - Outdoor unit: Malfunction of heat exchanger thermistor ............................................................... 30
2.5.23
L3-00 - Outdoor unit: Electrical box temperature rise problem................................................................... 30
2.5.24
2.5.25
L5-00 - Outdoor unit: Inverter instantaneous overcurrent .......................................................................... 32
2.5.26
P4-00 - Outdoor unit: Malfunction of radiating fin temperature sensor ..................................................... 33
2.5.27
U0-00 - Outdoor unit: Shortage of refrigerant ............................................................................................. 33
2.5.28
U2-00 - Outdoor unit: Defect of power supply voltage ................................................................................ 34
2.5.29
U4-00 - Indoor/outdoor unit communication problem................................................................................ 35
2.5.30
UA-00 - Indoor unit, outdoor unit mismatching problem ............................................................................ 36
2.6
Symptom based troubleshooting ................................................................................................................................... 38
2.6.1
Operation does not start................................................................................................................................ 38
2.6.2
Operation sometimes stops ........................................................................................................................... 38
2.6.3
Operation starts but the unit does not cool/heat ......................................................................................... 39
2.6.4
Operating noise and vibrations ...................................................................................................................... 40
2.6.5
Abnormal high pressure ................................................................................................................................. 41
2.6.6
Abnormal low pressure .................................................................................................................................. 42
2.6.7
Indoor fan starts operating but the compressor does not operate.............................................................. 43
2.6.8
Operation starts and the unit stops immediately.......................................................................................... 44
2.6.9
Operation stops, unit cannot start for a while .............................................................................................. 44
2.6.10
Unit discharges white mist ............................................................................................................................. 45
2.6.11
Swing flap does not operate .......................................................................................................................... 45
3.1
4-way valve...................................................................................................................................................................... 46
3.1.1
Checking procedures ...................................................................................................................................... 46
3.1.2
Repair procedures .......................................................................................................................................... 49
3.2
Compressor ..................................................................................................................................................................... 52
3.2.1
Checking procedures ...................................................................................................................................... 52
3.2.2
Repair procedures .......................................................................................................................................... 58
3.3
Expansion valve............................................................................................................................................................... 63
3.3.1
Checking procedures ...................................................................................................................................... 63
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01D - 2022.02
6
6
7
7
14
46

Advertisement